Descripción
Amprobe AMP-25 – AC/DC TRMS Mini-Clamp

AC/DC TRMS Mini-Clamp
- Autoranging
- DCA zero and data hold
- Auto power off
- Large LCD backlit display
- Safety Rated CAT III 600 V
Small size doesn’t mean small features. The Amprobe AMP-25 Mini-Clamp is pocket-sized, enabling quick and easy spot checks of electrical systems. With its rugged construction and CAT III 600V rating, the AMP-25 is a must-have professional troubleshooting tool for commercial electricians and electrical contractors.
The AMP-25 is designed to measure AC/DC load current and inrush current for motors. Essential features like True-RMS, non-contact voltage and low pass filter make this clamp stand tall next to clamps twice its size. With the AMP-25, you never have to sacrifice performance for size.
Troubleshoot electrical systems and measure AC/DC load current on exposed wires in a breaker panel.
Utilize the inrush current function for motor start-up monitoring.
The non-contact voltage (NCV) function checks for voltage presence.
Pocket-sized for quick and easy spot checks of electrical systems.
Convenience Without Compromise

Manufacturer Specs
| General Specifications | AMP-25 |
| Display | Digital: 6000 counts, updates 2/sec |
| Range | Autoranging |
| Overrange Indication | OL or -OL |
| Operating Temperature | 32 °F to 86 °F (0 °C to 30 °C), ≤ 80% RH 86 °F to 104°F (30°C to 40 °C), ≤ 75% RH 104 °F to 122°F (40°C to 50 °C), ≤ 45% RH |
| Operating Altitude | ≤ 2000 m |
| Storage Temperature | -4 °F to 140 °F (-20°C to +60°C) |
| Pollution Degree | 2 |
| Temperature Coefficient | 0.2 x (specified accuracy)/ °F(<64.4°F, >82.4°F)/ °C (<18 °C, >28 °C) |
| Vibration Requirement | MIL-PRF-28800F for A Class 2 |
| Drop Proof | 4 feet (120 cm) |
| Battery | Two 1.5 V LR44 size button batteries |
| Battery Life | 20 hours typical |
| Low Battery Indication | ![]() |
| Auto Power Off | Idle for 20 minutes |
| Overvoltage Category | CAT III 600 V |
| Safety Compliance | IEC/EN 61010-1, IEC/EN 61010-2-030, IEC/EN 61010-2-032 |
| EMC Compliance | IEC/EN 61326-1 |
| Agency Approval | ![]() |
| Dimensions (H x W x L) | 5.8 x 2.4x 1.3 in (147 x 60 x 32 mm) |
| Weight | Approximately 0.31 lb (140 g) with batteries installed |
| Jaw Opening & Conductor Diameter | 1.0 in (25 mm) max. |
| Features | AMP-25 | Best Accuracy |
| AC Current (1) | 60.00 / 300.0 A | +/-(1.5% + 5 LSD) @ 50 to 100 Hz = 3 A +/-(2.5% + 5 LSD) @ 100 to 400 Hz = 3 A |
| DC Current (2) | 60.00 / 300.0 A | +/-(1.5% + 5 LSD) @ 300 A range |
| Low Pass Filter | 300.0 A | +/-(3.5% + 5 LSD) @ 50 to 60 Hz = 3 A |
| True-RMS | • | |
| Inrush Current | • | |
| Non-Contact Voltage | • | |
| Data Hold | • |
Note (1): Crest Factor (C.F.) may be up to 3.0 as 4000 counts.
For non-sinusoidal waveforms:
Add 3.0% for C.F. 1.0 to 2.0
Add 5.0% for C.F. 2.0 to 2.5
Add 7.0% for C.F. 2.5 to 3.0
Position error of clamp: +/- 1.5 % of LCD reading
(2) Add 10 LSD in auto AC/DC sense mode
Tech Specs
Clamp Meters/Clamp Meters Template |
|
|---|---|
| True RMS | Yes |
| Maximum Current AC | 300 A |
| Maximum Current DC | 300 A |
| Maximum Conductor Size | 1 IN |
| Resistance | No |
| Capacitance | No |
| Auto Ranging/Manual | Auto Ranging |
| In-Rush Current | Yes |
Test Equipment General Attributes |
|
| Product Height | 1.75 IN |
| Product Length | 9.50 IN |
| Product Width | 6.50 IN |
| HTS/Schedule B Number | 9030.31.0000 |
| ECCN Number | EAR99 |
| Country of Origin | Taiwan |
| Shipping Height | 1.75 IN |
| Shipping Length | 9.50 IN |
| Shipping Width | 6.50 IN |










Valoraciones
No hay valoraciones aún.