Vaccine Kit LogTag UTREL30-16

  • Max Temperature: 104 F (40 C)
  • Min Temperature: -130 F
  • Power Source: Battery
  • Battery Life: 12 MONTHS (8760 h)
  • Input Source (Probe): External Probe
  • SAMPLE RATE/Intervals: Configurable from 30 seconds to 18 hours.

$9,034.37

In Stock
Agregar a cotización
SKU: DT1-VKLT-UTREL30-16 Categoría: Etiqueta:

Descripción

Logtag UTREL30-16 Vaccine Kit

  • Kit includes UTRED30-16, ST10S-15 extended probe (1.5m cable), NIST calibration certificate, USB cable
  • Read current temperature and latest Min-Max temperature at a glance
  • Audible alarm and flashing red LED signals a temperature alarm
  • Can be powered by 2x AAA batteries (user replaceable) if not external powered
  • Auto-pause function suspends alarm & statistic processing when the external probe is unplugged
Logtag Vaccine Kits
Kit Model Includes
Logtag TRED30-16 Vaccine Kit TRED30-16R, ST100K-15 Ext probe, Glycol buffer, NIST traceable calibration certificate
Logtag UTRED-16 Vaccine Kit Utred-16, ST100K-15 Ext probe, Glycol buffer, factory calibration certificate
Logtag UTRED30-WIFI Vaccine Kit Utred30-WIFI, ST100K-15 Ext Probe, Glycol buffer, NIST traceable calibration certificate
Logtag UTREL30-16 Vaccine Kit UTREL30-16, ST10S-15 Ext Probe, NIST traceable calibration certificate
Logtag UTREL30-16-WIFI Vaccine UTREL30-16, ST10M-15 Ext Probe, Buffer Kit, NIST traceable calibration certificate

The LogTag UTREL30-16 Temperature Recorder measures and stores up to 16,000 temperature readings.

It features a large easy-to-read display and is designed to show ‘at a glance’ if temperature excursions have occurred during the current day and up to the previous 29 days.

The alarm is triggered if temperature readings are outside pre-set alarm limits which is indicated by a large X on the display and, if configured, the audible alarm will sound.

Rated Absolute Accuracy

Rated Native Accuracy

Manufacturer Specs

Product Model UTREL30-16
External Sensor Measurement Range -90°C to +40°C (-130°F to +104°F)
Operating Temperature Range -30°C to +60°C (-22°F to +140°F)
Storage Temperature Range 0°C to +40°C (32°F to +104°F)
Rated Temperature Reading Resolution 0.1°C (0.2°F) for measurements -80°C to 10°C (-112°F to 50°F)
0.2°C (0.4°F) for measurements 10°C to 20°C (50°F to 68°F) and -90°C to -80°C (-130°F to -112°F)
0.3°C (0.5°F) for measurements 20°C to 30°C (68°F to 86°F)
0.5°C (0.9°F) for measurements 30°C to 40°C (86°F to 104°F)
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®
Sensor Reaction Time Typically less than 2 minutes(T90) in moving air (1m/s) for ST10S type
Rated Temperature Reading Accuracy Better than ±0.5°C for -20°C to +10°C (-4°F to 50°F)
Better than ±0.7°C for -50°C to -20°C (-58°F to -4°F) and +10°C to +30°C (50°F to 86°F)
Better than ±1°C for -80°C to -50°C (-112°F to -58°F ) and +30°C to +40°C (86°F to 104°F)
Better than ±1.8°C for -90°C to -80°C (-130°F to -112°F)
Recording Capacity 16,129 temperature readings. 67 days at 6 minute logging. Day summary statistics memory (for display on LCD): up to 30 days of Min/Max/duration and alarm trigger statistics.
Sampling Interval Configurable from 30 seconds to 18 hours
Logging Start Options Push button start (with configurable start delay from 1 minute to 72 hours) or specific date & time
Download Time Typically with full memory (16,129 readings) in less than 10 seconds
Environmental IP51 (when vertically mounted or hung with USB dust-cap in place)
Power Source 5V via micro USB socket or 2 x 1.5V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only)
Battery Life AAA battery up to 12 months – if unit is operated without power supply
Real Time Clock Built-in real time clock
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day)
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C)
Standard Remote Probe Cable Lengths Standard: 1.5m (4’11″). Extended: 3m (9’10″) (recommended maximum)
Remote Sensor Cable Type PTFE (FDA food contact rated) coaxial
Connection Interface USB 2.0 / Micro USB Socket
Size 141mm(H) x 72mm(W) x 18mm(T)
Weight 156g with AAA batteries, (132g – excluding probe and AAA batteries)
Case Material Polycarbonate

<h3″>Tech Specs

Dataloggers / Data Acquisition/Dataloggers for Environmental Variables/Temperature Dataloggers Templ

Max Temperature 104 F (40 C)
Min Temperature -130 F
Power Source Battery
Battery Life 12 MONTHS (8760 HR)
Input Source External Probe
SAMPLE RATE/Intervals Configurable from 30 seconds to 18 hours
Accuracy Better than ±0.5°C for -20°C to +10°C (-4°F to 50°F)
Better than ±0.7°C for -50°C to -20°C (-58°F to -4°F) and +10°C to +30°C (50°F to 86°F)
Better than ±1°C for -80°C to -50°C (-112°F to -58°F ) and +30°C to +40°C (86°F to 104°F)
Better than ±1.8°C for -90°C to -80°C (-130°F to -112°F)
LCD Screen Yes
Data Output Format pdf

Test Equipment General Attributes

Warranty 1 YEARS
Interfaces I/O USB
Storage Internal Memory
IP Rating IP51
Product Weight 156 GRAMS (0.344 LBS)
Product Height 5.55 IN
Product Length 0.7 IN
Product Width 2.83 IN
Shipping Weight 0.3955 LBS
Data Logging Yes
HTS/Schedule B Number 9025.19.8085
ECCN Number EAR99
Calibration Included NIST Calibration
Battery Type AAA, CR2032
Power Supply Voltage Battery Powered
Country of Origin China

Descargar Ficha técnica

Valoraciones

No hay valoraciones aún.

Sé el primero en valorar “Vaccine Kit LogTag UTREL30-16”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *