Descripción
Oakton WD-20250-20 Digi-Sense Pro 4-Input Data Logging Thermocouple Thermometer, Type K, NIST Traceable Cal

Rugged, heavy-duty construction protects against knocks and jars
The Digi-Sense Professional Thermocouple Thermometer (Model 20250-20) with Four Type K Inputs, Data Logging, and Optional Infrared Wand offers fast response and high accuracy. This heavy-duty meter works with up to four type K thermocouples and one optional infrared probe*. Advanced features include data logging, USB interface, relative time clock, offset compensation, temperature differential, data Hold, Max/Min/Avg readings, and automatic power-off. The instrument is fully tested and calibrated to NIST-traceable standards. Careful use of this meter will provide years of reliable service.
These professional type K thermometers provide accurate and… reliable temperature measurement in an ergonomic design. Double-molded heavy-duty housing provides superior protection, making them ideal for tough applications. Plus the NIST-traceable precalibration means you get reliable measurements right out of the box, saving you time and money!
All models feature Min/Max/Avg, Hold, °F/°C or Kelvin (K) selectable units, relative time stamp on Min/Max/Avg, electronic offset function, temperature differential, backlit display, and auto
These meters also feature an infrared input that accepts an optional IR wand for noncontact measurements of objects that are difficult or dangerous to reach; order wand 20250-24 separately below. The IR temperature reading can be used as a unique input when calculating temperature differential. The IR wand has a distance-to sight ratio of 8:1 and temperature range of –31 to 1022°F (–35 to 550°C).
Model 20250-20 includes all the same features as 20250-17 plus four independent channels with data logging up to 10,000 readings. Easily download the data to a PC via USB interface, and analyze the data graphically with included software.
Applications
- Agricultural.
- Educational.
- Food processing
- HVAC
- Industrial
- Laboratory
- R&D
- Preventive maintenance
Manufacturer Specs
| Oakton WD-20250-20 General Specifications | |
| Meter Measurement Type | Thermocouple |
| Number Of Probe Channels | 4 |
| Types Of Probes Accepted | Type K |
| Min Temperature (° F) | -328 |
| Max Temperature (° F) | 2501 |
| Min Temperature (° C) | -200 |
| Max Temperature (° C) | 1372 |
| Accuracy | ±0.15% of reading 1.8°F; ±0.5% of reading 3.6°F below -148°F [±0.15% of reading 1.0°C; ±0.5% of reading 2.0°C below -100°C] |
| Resolution | 0.1°; 1° above 999.9° |
| Min IR Temperature (° F) | 1022 |
| Min IR Temperature (° C) | 550 |
| Max IR Temperature (° F) | -35 |
| Max IR Temperature (° C) | -31 |
| IR Temperature Accuracy | ±2% of reading 3.6°F; ±9.0°F below 14°F [±2% of reading 2.0°C; ±5°C below -10°C] |
| Output | USB |
| Data Logging | Yes |
| Memory Capacity | 10000 data points |
| Low Battery Indicator | Yes |
| Display Type | Backlit LCD |
| Height (in) | 8 |
| No. of Probe(s) Included | 4 |
| Battery | 9v Battery (1) |
| Description | Pro 4-Input Data Logging Thermocouple Thermometer, Type K, NIST Traceable Cal |
Tech Specs
Thermometers/Contact Thermometers Template |
|
|---|---|
| Type (Contact Thermometers) | Thermocouple |
| Types RTD/Thermocouples Accepted | K |
| Temperature Range of Probe Accepted | 1372 C (2501.6 F) |
| Number of Probe Inputs/Channels | 4 |
| Resolution (thermometers) | 0.1°; 1° above 999.9° |
Dataloggers / Data Acquisition/Dataloggers for Environmental Variables/Temperature Dataloggers Templ |
|
| Accuracy | ±0.15% of reading 1.8°F; ±0.5% of reading 3.6°F below -148°F [±0.15% of reading 1.0°C; ±0.5% of reading 2.0°C below -100°C] |
Test Equipment General Attributes |
|
| Interfaces I/O | USB |
| Product Height | 8 IN |
| Data Logging | Yes |
| HTS/Schedule B Number | 9025.19.8080 |
| ECCN Number | EAR99 |
| Calibration Included | NIST Calibration |
| Battery Type | 9v |
| Power Supply Voltage | Battery Powered |




Valoraciones
No hay valoraciones aún.