Descripción
Comet H5521 Remote CO2 Concentration with Ethernet Interface and Two Relays

- Complex solution for data acquisition and analysing
- Easy to use and high flexible database software for Comet Sensors
- Free configuration utility for COMET sensor
- Basic data acquisition utility for COMET Sensors
The CO2 measurement is based on a 2-source, 2-beam process. CO2 measurement with long-term stability is guaranteed thanks to the proven non-dispersive infrared (NDIR) CO2 measurement cell. The unique patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field.
The CO2 measurement is based on a 2-source, 2-beam process. CO2 measurement with long-term stability is guaranteed thanks to the proven non-dispersive infrared (NDIR) CO2 measurement cell. The unique patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field.
High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
The CO2 measurement is based on a 2-source, 2-beam process. CO2 measurement with long-term stability is guaranteed thanks to the proven non-dispersive infrared (NDIR) CO2 measurement cell. The unique patented auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical recalibration in the field.
These days there is a high demand for on-line monitoring and uninterruptable records of different type of values. With very fast development of computer technologies, it is still easier and easier to connect different kind of monitoring devices directly to Ethernet lines, to the places where it was not possible before. If the Ethernet net has direct connection to the internet. This high requirements could be done easily by Web Sensors and sensors with Ethernet output which can ensure long term reliability, stable parameters and very easy installation and usage. The devices can be protected against blackouts and data loss at the customer’s site. Of course PoE supply is an option.
Continuous monitoring of critical parameters such as temperature and relative humidity can be very easily done by the help of Web Sensors. This production line consists of sensors for measuring temperature, relative humidity, CO2 concentration, atmospheric pressure, and the 4-20mA signal. Most sensors are equipped with an LCD display and can be easily incorporated into the existing network infrastructure.
The Web Sensors evaluate the measured values and in case of exceeding the alarm limits, the unit will send an email to a pre-set address, so this ensures that you are always informed of the conditions in your offices, server rooms, warehouses and factories, and everywhere where is necessary to monitor the supported values. By connecting directly to a computer network the thermometer or humidity meter can be integrated into the control systems of different manufacturers using SNMP, MODBUS TCP, SOAP, syslog. Of course data in many formats is also available, for example XML and so on.
Applications
- Building management
- Factories and manufacturing
- Warehouses

Manufacturer Specs
| Comet H6520 Specifications | |
| Technical Parameters | Value |
| Output | Ethernet |
| Measured Value | CO2 + Temperature + Relative Humidity |
| Construction Type | Ambient Air |
| Design | Industrial |
| Temperature Measuring Range | -30 to 60 °C |
| Relay Output | Yes |
| Two-State Input | No |
| Lcd Display | Yes |
| PoE | No |
| Range of CO2 concentration measurement | 0 to 2000ppm |
| Accuracy of CO2 concentration measurement | ±(50ppm +2% from reading) at 25°C and 1013hPa |
| Optional range of CO2 concentration measurement | 0 to 10000ppm ±(100ppm +5% from reading) at 25°C and 1013hPa |
| Relative humidity range | 0 to 100% |
| Accuracy of relative humidity measurement | ±2.5% relative humidity from 5 to 95% at 23°C |
| Accuracy of temperature output | ±0.4°C |
| Resolution | 0.1°C, 0.1%RH, 1ppm |
| Measuring interval of temperature and relative humidity | 2s |
| Measuring interval of CO2 | 15s |
| Available temperature units | degrees Celsius, degrees Fahrenheit |
| Computed values | dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy |
| Accuracy and range of dew point temperature output – for more details see graphs in manual | ±1.5°C at ambient temperature T<25°C and RH>30% range -60 to +80°C |
| Accuracy and range of absolute humidity output | ±1.5g/m3 at ambient temperature T < 25°C range 0 to 400g/m3 |
| Accuracy and range of specific humidity output | ±2g/kg at ambient temperature T < 35°C range 0 to 550g/kg |
| Accuracy and range of mixing ratio output | ±2g/kg at ambient temperature T < 35°C range 0 to 995g/kg |
| Accuracy and range of specific enthalpy output | ±3kJ/kg at ambient temperature T < 25°C range: 0 to 995kJ/kg |
| Temperature compensation of the humidity sensor | all temperature range |
| Temperature operating range | -30 to +60°C |
| IP protection | IP30 |
| Number of relay outputs | 2 |
| Maximum switching voltage, current and power of relay output | 50V, 2A, 60VA |
| Audible alarm | built-in beeper – switchable |
| LAN connection | RJ-45 connector, 10Base-T or 100Base-TX |
| Communication protocols | WWW, ModbusTCP, SNMPv1, SOAP |
| Alarm protocols | E-mail (SMTP authentication is supported), SNMP Trap, Syslog |
| Configuration | T-Sensor, Telnet, keyboard |
| Power | 9 to 30Vdc, power consumption approximately 1W |
| Power connector | co-axial, diameter 5.5 x 2.1mm |
| Dimensions | 136 x 213 x 45mm (W x H x D), stem length 75mm |
| Weight | approximately 340g |
| Warranty | 3 years |
Tech Specs
Test Equipment General Attributes |
|
|---|---|
| Product Weight | 1 LBS |
| Shipping Weight | 1.15 LBS |
| Country of Origin | Czech Republic |




Valoraciones