Descripción
Fluke 107 ESP Palm-sized, CAT III Digital Multimeter

- Professional measurements in the palm of your hand
- AC/DC Voltage to 600V
- AC/DC Current to 10A
- Resistance & Continuity to check for broken wires
- Data hold & backlit display to keep you working safe and fast
The Fluke 107 is a compact, easy-to-use multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time.
Complete Test Functions
- Including AC and DC voltage measurement
- AC and DC current measurement
- Resistance measurement
- Capacitance measurement
- Diode measurement
- Frequency and duty cycle test and other functions to meet basic electrical maintenance, electrical measurement, and electronic measurement applications
Manufacturer Specs
| Electrical specifications | |||
| Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]) | |||
| Function | Range | Resolution | Accuracy |
| AC volts (40 Hz to 500 Hz)1 | 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
1.0 % + 3 |
| DC volts | 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
0.5 % + 3 |
| AC millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 |
| Diode test2 | 2.000 V | 0.001 V | 10 % |
| Resistance (ohms) | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
| Capacitance3 | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
| Frequency4 (10 Hz to 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
0.1 % + 3 |
| Duty cycle4 | 0.1 % to 99.9 % | 0.1 % | 1% typical5 |
| AC current (40 Hz to 200 Hz) | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 |
| DC current | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 |
| Backlight | – | – | Yes |
| 1. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2. Typically, open circuit test voltage is 2.0 V and short circuit current is < 0.6 mA. 3. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range). 4. All AC, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 5. Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %. |
|||
| Function | Overload protection | Input impedance (nominal) | Common mode rejection ratio | Normal mode rejection ratio |
| AC volts | 600 V1 | > 10 MΩ < 100 pF2 |
> 60 dB at dc, 50 Hz or 60 Hz | – |
| AC millivolts | 600 mV | >1M <100 pF |
> 80 dB at 50 Hz or 60 Hz | – |
| DC volts | 600 V2 | > 10 MΩ < 100 pF |
> 100 dB at dc, 50 Hz or 60 Hz | > 45 dB at 50 Hz or 60 Hz |
| 1. 6 x 105 V Hz Max 2. For mV (AC), input impedance is approximately 1 MΩ. |
||||
| General specifications | |
| Maximum voltage between any terminal and earth ground | 600 V |
| Display (LCD) | 6000 counts, updates 3/sec |
| Battery type | 2 AAA, NEDA 24A, IEC LR03 |
| Battery life | 200 hours minimum |
| Temperature | Operating: 0 °C to 40 °C Storage: -30 °C to 60 °C |
| Relative humidity | Operating Humidity: Non-condensing when < 10°C ≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C Operating Humidity, 40 MΩ Range: ≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C |
| Altitude | Operating: 2000 m Storage: 12,000 m |
| Temperature coefficient | 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) |
| Fuse protection for current inputs | 11 A, 1000 V Fast Fuse, Fluke specified part only |
| Size (HxWxL) | 142 mm x 69 mm x 28mm |
| Weight | 200 g |
| IP rating IEC 60529: | IP 40 |
| Safety | IEC 61010-1: 600 V CAT III, Pollution Degree 2 |
| Electromagnetic environment | IEC 61326-1: portable |
| Electromagnetic compatibility | Applies to use the Korea only. Class A Equipment (Industrial broadcasting and communication equipment)1 |
| Warranty | One year |
| 1. This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in home. | |
Tech Specs
Multimeters Template |
|
|---|---|
| Style | Hand-Held |
| Measures DC V | Yes |
| True RMS | Yes |
| Maximum Voltage AC | 600 V |
| Resolution AC Volts | 600 mV |
| Maximum Voltage DC | 600 V |
| Maximum Current AC | 10 A |
| Maximum Current DC | 10 A |
| Counts | 6000 . |
| Backlight | Yes |
| Resistance | Yes |
| Frequency | Yes |
| Capacitance | Yes |
| Temperature | Yes |
| Diode Testing | Yes |
| CAT Rating | III |
| CAT Voltage | 600 V |
| Overload Protector | Yes |
| Data Hold | Yes |
Test Equipment General Attributes |
|
| Unique Features | Range: 0.1 % to 99.9 % Resolution: 0.1 % Accuracy: 1% typical |
| Warranty | 1 YEARS |
| IP Rating | IP40 |
| Product Weight | 200 GRAMS (0.441 LBS) |
| Product Height | 142 MM (5.59 IN) |
| Product Length | 28 MM (1.10 IN) |
| Product Width | 69 MM (2.72 IN) |
| HTS/Schedule B Number | 9030.32.0000 |
| ECCN Number | 3A992 |
| Battery Type | AAA |
| Power Supply Voltage | Battery Powered |
| Country of Origin | China |
| Shipping Height | 6.25 IN |
| Shipping Length | 4.19 IN |
| Shipping Width | 2.13 IN |




Valoraciones
No hay valoraciones aún.