Descripción
The best of the basics.
With true-rms ac voltage and current measurements, the Fluke 373 Clamp Meter reads up to 600 A ac and 600 V ac or dc.
Be ready for anything.
The new Fluke 373 Clamp Meter offers improved performance perfect for any ac only current measurement situations. Featuring true-rms ac voltage and current measurements, and resistance measurement up to 6000Ω with continuity detection, the Fluke 373 is everything you need, plus a little more.
| Fluke 365 | Fluke 373 | Fluke 374 | Fluke 375 | Fluke 376 | Fluke 381 | |
| Measure ac current | 200.0 A | 600.0 A | 600.0 A | 600.0 A | 999.9 A | 999.9 A |
| Measure ac current via iFlex | 2500 A | 2500 A | 2500 A | 2500 A | ||
| Measure ac voltage | 600.0 V | 600.0 V | 600.0 V | 600.0 V | 1000.0 V | 1000.0 V |
| Measure continuity | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω |
| Measure dc current | 200.0 | 600.0 | 600.0 | 999.9 | 999.9 | |
| Measure dc voltage | 600.0 V | 600.0 V | 600.0 V | 1000.0 V | 1000.0 V | |
| Measure resistance | 6,000 Ω | 6,000 Ω | 6,000 Ω | 60 Ω | 60 Ω | 60 Ω |
| Measure frequency | 500 Hz | 500 Hz | 500 Hz | |||
| Measure inrush | 100 mS | 100 mS | 100 mS | 100 mS | ||
| Work in poorly lit areas | Backlight | Backlight | Backlight | Backlight | Backlight | Backlight |
| Measure non-linear loads | True-rms | True-rms | True-rms | True-rms | True-rms | True-rms |
Manufacturer Specs
| Model | ![]() 381 |
![]() 376 |
![]() 375 |
![]() 374 |
![]() 373 |
![]() 365 |
|
| iFlex flexible current probe | Included | Included | Compatible | Compatible | – | – | |
| AC current (jaw) | Range | 999.9 A | 999.9 A | 600.0 A | 600.0 A | 600.0 A | 200.0 A |
| Accuracy | 2 % ± 5 digits | 2 % ± 5 digits | 2 % ± 5 digits | 2 % ± 5 digits | 2 % ± 5 digits | 2 % ± 5 digits | |
| AC current (iFlex™) | Range | Range | 2500.0 A | 2500.0 A | 2500.0 A | – | – |
| Accuracy | 3 % ± 5 digits | 3 % ± 5 digits | 3 % ± 5 digits | 3 % ± 5 digits | – | – | |
| DC current | Range | 999.9 A | 999.9 A | 600.0 A | 600.0 A | – | – |
| Accuracy | 2 % ± 5 digits | 2 % ± 5 digits | 2 % ± 5 digits | 2 % ± 5 digits | – | 2 % ± 5 digits | |
| AC voltage | Range | 1000.0 V | 1000.0 V | 600.0 V | 600.0 V | 600.0 V | 600.0 V |
| Accuracy | 1.5 % ± 5 digits | 1.5 % ± 5 digits | 1.5 % ± 5 digits | 1.5 % ± 5 digits | 1 % ± 5 digits | 2 % ± 5 digits | |
| DC voltage | Range | 1000.0 V | 1000.0 V | 600.0 V | 600.0 V | 600.0 V | 600.0.0 V |
| Accuracy | 1 % ± 5 digits | 1 % ± 5 digits | 1 % ± 5 digits | 1 % ± 5 digits | 1 % ± 5 digits | 2 % ± 5 digits | |
| Resistance | Range | 60,000 Ω | 60,000 Ω | 60,000 Ω | 6000 Ω | 6000 Ω | 6000 Ω |
| Accuracy | 1 % ± 5 digits | 1 % ± 5 digits | 1 % ± 5 digits | 1 % ± 5 digits | 1 % ± 5 digits | 1 % ± 5 digits | |
| Capacitance | Range | – | 1 µF to 1000 µF | 1 µF to 1000 µF | 1 µF to 1000 µF | 1 µF to 1000 µF | – |
| Accuracy | – | 1.0 % ± 4 digits | 1.0 % ± 4 digits | 1.0 % ± 4 digits | 1.9 % ±2 digits | – | |
| mV dc range | – | 500 mV | 500 mV dc | – | – | – | |
| Continuity | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω | ≤ 30 Ω | |
| Frequency | 5 Hz to 500 Hz | 5 Hz to 500 Hz | 5 Hz to 500 Hz | – | – | – | |
| Remote display | Yes | – | – | – | – | – | |
| AC response | True-RMS | True-RMS | True-RMS | True-RMS | True-RMS | True-RMS | |
| Backlight | Yes | Yes | Yes | Yes | Yes | Yes | |
| Data hold | Yes | Yes | Yes | Yes | Yes | Yes | |
| Min/Max/Avg | Yes | Yes | Yes | Yes | – | – | |
| Inrush | Yes | Yes | Yes | Yes | – | – | |
| Size (HxWxD) | 280 mm x 88 mm x 50 mm (11 in x 3.5 in x 2 in) | 248 mm x 85 mm x 45 mm (9.8 in x 3.3 in x 1.8 in) | 248 mm x 85 mm x 45 mm (9.8 in x 3.3 in x 1.8 in) | 248 mm x 85 mm x 45 mm (9.8 in x 3.3 in x 1.8 in) | 232 mm x 85 mm x 45 mm (9 in x 3.3 in x 1.8 in) | 225 mm x 65 mm x 46 mm (8.9 in x 2.6 in x 1.8 in) | |
| Max wire diameter | 750 MCM | 750 MCM | 750 MCM | 750 MCM | 750 MCM | 4/0 | |
| Weight | 540 g (19 oz) | 375 g (13.2 oz) | 375 g (13.2 oz) | 375 g (13.2 oz) | 370 g (13 oz) | 275 g (10 oz) | |
| Category rating | CAT III 1000 V CAT IV 600 V |
CAT III 1000 V CAT IV 600 V |
CAT III 1000 V CAT IV 600 V |
CAT III 1000 V CAT IV 600 V |
CAT III 1000 V CAT IV 600 V |
CAT III 600 V | |
| Warranty | Three years | ||||||
Tech Specs
Clamp Meters/Clamp Meters Template |
|
|---|---|
| True RMS | Yes |
| Maximum Current AC | 600 A |
| Maximum Voltage AC | 600 V |
| Maximum Voltage DC | 600 V |
| Maximum Conductor Size | 1 IN |
| Resistance | Yes |
| Capacitance | Yes |
| Auto Ranging/Manual | Auto Ranging |
| In-Rush Current | No |
Test Equipment General Attributes |
|
| Warranty | 3 YEARS |
| Safety Approval | CE, CSA |
| Product Weight | 2 LBS |
| Product Height | 3.25 IN |
| Product Length | 11.75 IN |
| Product Width | 4.50 IN |
| Data Logging | No |
| HTS/Schedule B Number | 9030.31.0000 |
| ECCN Number | 3A992 |
| Calibration Included | None |
| Power Supply Voltage | Battery Powered |
| Country of Origin | Taiwan |










Valoraciones