Description
Accuracy and diagnostic functions for maximum industrial productivity.
Fluke 80 Series V has replaced series 80 Series III.
The new Fluke 87V has improved measurement functions, trouble-shooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution and electro-mechanical equipment.
The New 80 Series consists of the following models:
- Fluke 83V Industrial DMM
- Fluke 87V True RMS Industrial DMM
- Fluke 87-5E/2 Industrial Electricians Combo Kit (Replaces 87 V/E)
The 87V operates very similar to the classic 87, but with more problem solving power, safety, convenience and impact protection.
The new 80 series V are independently tested to comply with the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600V/CAT III 1000V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.
New features for maximum productivity.
- Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (87V)
- Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (87V)
- Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
- Large digit display with bright, two-level backlight makes the 80 Series V significantly easier to read than older models
Electrical safety.
All inputs are protected to Category III, 1000 V and Category IV 600 V. They can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals.
- The new Fluke 87V is designed specifically to handle complex signals produced by adjustable speed motor drives. Think of the potential productivity you’ll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time. Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
- Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
- Measure AC current with an optional current clamp accessory
- Compare readings from the 87V with the display on the ASD
- Special shielding blocks high frequency, high-energy noise generated by large drive systems
![]() |
![]() |
| Complex PWM drive signals are not a problem for the Fluke 87V | Pulse-width modulated detail of 50 Hz motor drive output voltage. 1000 V, 50 micro-second pulses can cause erratic behavior in some test equipment |
![]() |
This meter reading of the output voltage is with the low pass filter enabled. The reading compares well with the drive’s display value.
This meter reading without the low pass filter enabled is approximately 30% higher than the actual drive output voltage. This reading utilizes the meters full 20 kHz bandwidth. Many other multimeters available today will not provide readings which compare to the drives display value. |
See how the new 87V compares to the original Fluke 87:
![]() |
![]() |
||
| Function | Original 87 | 87V | Productivity Increase |
| Selectable filter for motor drives | No | Yes | Accurate voltage and frequency measurements on pulse width modulated signals |
| Built in thermometer | No | Yes | No need to carry a separate thermometer |
| Capacitance | 5 nf to 5 μF | 5 nf to 10,000 μF | Measure more capacitors |
| VDC accuracy and resolution | 0.1 %, 10 μV | 0.05 %, 10 μV | Precise measurements in a hand held package |
| Display digits | 13.5 X 7 mm | 15.25 X 8.5 mm | 30 % larger makes it easy to read |
| Backlight | Green | 2-level, bright white | Easier to read in dark locations |
| Magnetic hanger | No | Optional | Position meter for easy viewing |
| Peak capture | 1ms | 250 μS | Record intermittent problems 4 times faster |
| CAT electrical safety rating | No | Yes, 2nd edition ANSI and IEC | Increased protection from 8kV spikes that can cause arc flash |
| Battery door | No | Yes | Change battery quickly without breaking cal seal |
| Warranty | Expired | Limited Lifetime | Lower cost of ownership |
Measures:
- Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment (87-5, 87-5/E Kit)
- True-rms ac voltage and current for accurate measurements on non linear signals (87-5, 87-5/E Kit)
- Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument (87-5, 87-5/E Kit)
- Measure up to 1000 V AC and DC
- Measure up to 10 A (20 A for 30 seconds)
- 10,000 µF capacitance range
- Frequency to 200 kHz and % duty cycle
- Peak capture to record transients as fast as 250 µs (87-5, 87-5/E Kit)
- 4½ digit mode (87-5, 87-5/E Kit)
Manufacturer Specs
| DCV | |
| Maximum Voltage | 1000V |
| Accuracy | ±(0.1%+1) |
| Maximum Resolution | 100 μV |
| ACV | |
| Maximum Voltage | 1000V |
| Accuracy | ±(0.5%+2) |
| AC Bandwidth | 5kHz *with low pass filter; 3db @ 1kHz |
| Maximum Resolution | 0.1 mV |
| DC Current | |
| Maximum Amps | 10A |
| Amps Accuracy | ±(0.4%+2) |
| Maximum Resolution | 0.01 mA |
| AC Current | |
| Maximum Amps | 10A |
| Amps Accuracy | ±(1.2%+2) |
| Maximum Resolution | 0.1 μA |
| Resistance | |
| Maximum Resistance | 50 MΩ |
| Accuracy | ±(0.4%+1) |
| Maximum Resolution | 0.1Ω |
| Capacitance | |
| Maximum Capacitance | 9,999 μF |
| Accuracy | ±(1%+2) |
| Maximum Resolution | 0.01 nF |
| Frequency | |
| Maximum Frequency | 200 KHz |
| Accuracy | ±(0.005%+1) |
| Maximum Resolution | 0.01 Hz |
| Duty Cycle | |
| Maximum Duty Cycle | 99.9 % |
| Accuracy | ±(0.2 per KHz +0.1%) |
| Maximum Resolution | 0.1 % |
| Temperature Measurement | |
| 87 V | -200.0°C – 1090°C |
| 87 V/E | -328.0°F – 1994.0°F, 1.0% excluding probe |
| 80 BK Temperature Probe | |
| 87 V | -40°C – 260°C |
| 87 V/E | -40°F – 500°F, 2.2°C or 2% whichever is greater |
| Conductance | |
| Maximum Conductance | 60.00 nS |
| Accuracy | ±(1.0%+10) |
| Maximum Resolution | 0.01 nS |
| Operating Range | |
| Operating Temperature | -20°C – 55°C |
| Storage Temperature | -40°C – 60°C |
| Physical | |
| Dimensions | 5.2 cm x 9.8cm x 20.1 cm (2.06” x 3.86” x 7.93”) |
| Weight | 624 g (22 oz.) |
Tech Specs
Multimeters Template |
|
|---|---|
| Style | Hand-Held |
| Measures AC V | Yes |
| Measures DC V | Yes |
| Measures AC A | Yes |
| Measures DC A | Yes |
| True RMS | Yes |
| Maximum Voltage AC | 1000 V |
| Resolution AC Volts | 0.1 mV |
| Maximum Voltage DC | 1000 V |
| Resolution DC Volts | 0.1 mV |
| Maximum Current AC | 10 A |
| Minimum Current AC | 0.1 uA (0.00010 mA) |
| Resolution AC Current | 0.1 uA (0.00010 mA) |
| Maximum Current DC | 10 A |
| Minimum Current DC | 0.1 uA (0.00010 mA) |
| Resolution DC Current | 0.1 uA (0.00010 mA) |
| Basic Accuracy V DC | ± (0.05 % + 1) |
| # Digit Display | 4.5 |
| Counts | 6000 . |
| Backlight | Yes |
| Manual/Autoranging | Both |
| Decibels | No |
| Resistance | Yes |
| Frequency | Yes |
| Capacitance | Yes |
| Temperature | Yes |
| Diode Testing | Yes |
| CAT Rating | IV |
| CAT Voltage | 1,000 V, 600 V |
| Intrinsically Safe | No |
| Peak Hold | Yes |
| Overload Protector | Yes |
| Kelvin 4-Wire Measurement Capability | No |
| Wireless Display | No |
| Data Hold | Yes |
| Low-Pass Filter | Yes |
| Duty Cycle % | Range: 0.0 to 99.9 % Accuracy: Within ± (0.2 % per kHz + 0.1 %) for risetimes < 1 μs |
Test Equipment General Attributes |
|
| Unique Features | •Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment •Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument •Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks •Large digit display with bright, two-level backlight makes the 87V significantly easier to read than older models •True-rms ac voltage and current for accurate measurements on non linear signals •Selectable filter for accurate voltage and frequency measurements on motor drives •0.05 % dc accuracy •6000 counts, 3-3/4 digits •4-1/2 digit mode for precise measurements (20,000 counts) •Measure up to 1000 V ac and dc •Measure up to 10 A, 20 A for up to 30 seconds •Built in thermometer lets you carry one less tool (TC probe included) •Frequency to 200 kHz and % duty cycle •Resistance, continuity and diode test |
| Warranty | 10 YEARS |
| Additional Info/Comments | •10,000 µF capacitance range for components and motor caps •Min/Max-Average recording with Min/Max Alert to capture variations automatically •Peak capture to record transients as fast as 250 µs •Relative mode to remove test lead interference from low ohms measurements •Auto and manual ranging for maximum flexibility •Touch Hold to capture stable readings avoiding noisy signals •Large display digits and two-level bright white backlight for increased visibility •Analog bargraph for fast changing or unstable signals •Input Alert provides audible warning against wrong use of input jacks •Improved selectable sleep mode for long battery life •Access door for fast battery changes without breaking the calibration seal •”Classic” design with new removable holster with built in test lead and probe storage •Lifetime warranty |
| Safety Approval | CSA, UL |
| Interfaces I/O | Other, Analog Input |
| Product Weight | 0.78 LBS |
| Product Height | 1.25 IN |
| Product Length | 7.35 IN |
| Product Width | 3.41 IN |
| Shipping Weight | 1.37 LBS |
| Data Logging | No |
| HTS/Schedule B Number | 9030310000 |
| ECCN Number | 3A992 |
| Calibration Included | Factory Calibration |
| Battery Type | 9v |
| Power Supply Voltage | Battery Powered |
| Country of Origin | United States |
| Shipping Height | 5.91 IN |
| UPC | 095969245241 |
| Shipping Length | 12.99 IN |
| Shipping Width | 11.02 IN |