Descripción
Oakton 20250-94Dual-Input Data Logging Thermometers
- Electronic Offset function allows compensation of probe errors
- Data logging models record up to 16,000 measurements for expanded data analysis capability
- Data logging models feature software that provides quick and easy data interpretation
- Temperature differential plus Min, Max, and Avg readings, for quick analysis of the object
The Digi-Sense Dual-Input Thermometers with Data Logging (20250-92, -94, -96) offer fast response and high accuracy. Advanced features include data logging, USB interface, relative time clock, offset compensation, temperature differential, data Hold, Max/Min/Avg readings, and auto power-off. The instrument is fully tested and calibrated to NIST-traceable standards. Careful use of this meter will provide years of reliable service.
The Digi-Sense Professional Single-Input Thermometers offer fast response and laboratory accuracy. Features include automatic backlight, Max/Min readings, and automatic power-off. These thermometers provide precise measurements when accuracy is a must, delivering dependable results every time! Each model is packed with distinctive features for use in a wide array of applications. Robust and reliable constructed to protects against knocks and jars. These thermometers produce a high degree of accuracy, with a rapid response time, and exceptional battery life of up to 3000 hours.
Digi-Sense instrument are fully tested and calibrated to NIST-traceable standards, saving you hundreds of dollars and extra waiting time to calibrate separately.
Manufacturer Specs
| Oakton 20250-94 General Specifications | |
| Meter Measurement Type | Thermistor |
| Number Of Probe Channels | 2 |
| Types Of Probes Accepted | 400 Series |
| Min Temperature (° F) | -40 |
| Max Temperature (° F) | 257 |
| Min Temperature (° C) | -40 |
| Max Temperature (° C) | 125 |
| Accuracy | ±0.9°F (±0.5°C) from 32 to 158°F, (0 to 70°C); ±2°F (1°C) outside range |
| Resolution | 0.1°F (0.1°C) |
| Data Logging | Yes |
| Memory Capacity | 16000 data points |
| Alarm | Yes |
| Low Battery Indicator | Yes |
| Display Type | Large, dual, backlit LCD |
| Battery Life | 300 hours |
| Battery | One 9V battery (included) |
| Description | Thermistor Thermometer, 2-Input Data Logging, NIST Traceable Cal |
Tech Specs
Thermometers/Contact Thermometers Template |
|
|---|---|
| Type (Contact Thermometers) | Thermistor |
| Temperature Range of Probe Accepted | 125 C (257 F) |
| Number of Probe Inputs/Channels | 2 |
| Resolution (thermometers) | 0.1°F (0.1°C) |
Dataloggers / Data Acquisition/Dataloggers for Environmental Variables/Temperature Dataloggers Templ |
|
| Accuracy | ±0.9°F (±0.5°C) from 32 to 158°F, (0 to 70°C); ±2°F (1°C) outside range |
Test Equipment General Attributes |
|
| Data Logging | Yes |
| HTS/Schedule B Number | 9025.19.8085 |
| ECCN Number | ERA99 |
| Calibration Included | NIST Calibration |
| Battery Type | 9v |
| Power Supply Voltage | Battery Powered |
| Country of Origin | China |




Valoraciones
No hay valoraciones aún.