Data Logger Oakton 20250-96 Dual-Input Data Logging Thermometers

Digi-Sense RTD Thermometer, 2-Input Data Logging, NIST-Traceable Calibration

  • Reliable measurements, guaranteed!
  • NIST-traceable certificate included
  • Heavy duty construction to protect against knocks and jars.
  • Super lager LCD for easy viewing of data
  • Accepts a wide variety of probes
  • Min, Max, and Avg readings, for quick analysis of the object
  • Electronic Offset function allows compensation of probe errors
  • Data logging models record up to 16,000 measurements for expanded data analysis capability
  • Data logging models feature software that provides quick and easy data interpretation
  • Temperature differential plus Min, Max, and Avg readings, for quick analysis of the object
  • Relative time clock on Min, Max, and Avg provides a time reference for major events.

$7,941.60

In Stock
Agregar a cotización
SKU: DT178-DTOA-20250-96 Categorías: , Etiqueta:

Descripción

Oakton 20250-96DS Dual-Input Data Logging Thermometers

  • Reliable measurements, guaranteed!
  • NIST-traceable certificate included
  • Heavy duty construction to protect against knocks and jars.
  • Super lager LCD for easy viewing of data

The Digi-Sense Dual-Input Thermometers with Data Logging (20250-92, -94, -96) offer fast response and high accuracy. Advanced features include data logging, USB interface, relative time clock, offset compensation, temperature differential, data Hold, Max/Min/Avg readings, and auto power-off. The instrument is fully tested and calibrated to NIST-traceable standards. Careful use of this meter will provide years of reliable service.

The Digi-Sense Professional Single-Input Thermometers offer fast response and laboratory accuracy. Features include automatic backlight, Max/Min readings, and automatic power-off. These thermometers provide precise measurements when accuracy is a must, delivering dependable results every time! Each model is packed with distinctive features for use in a wide array of applications. Robust and reliable constructed to protects against knocks and jars. These thermometers produce a high degree of accuracy, with a rapid response time, and exceptional battery life of up to 3000 hours.

Digi-Sense instrument are fully tested and calibrated to NIST-traceable standards, saving you hundreds of dollars and extra waiting time to calibrate separately.

Manufacturer Specs

Oakton 20250-96 General Specifications
Meter Measurement Type RTD
Number Of Probe Channels 2
Types Of Probes Accepted RTD
Min Temperature (° F) -320
Max Temperature (° F) 1562
Min Temperature (° C) -200
Max Temperature (° C) 850
Accuracy ±1.5°F (0.8°C) from -148 to 392°F (-99.9 to 199.9°C); ±2°F (1°C) ±0.5% of reading outside range
Resolution .1°F (0.1°C) from 148 to 1562°F (-99.9 to 850°C); 1°F (1°C) outside range
Data Logging Yes
Memory Capacity 16000 data points
Alarm Yes
Low Battery Indicator Yes
Display Type Large, dual, backlit LCD
Battery Life 300 hours
Battery One 9V battery (included)
Description RTD Thermometer, 2-Input Data Logging, NIST Traceable Cal

Tech Specs

Thermometers/Contact Thermometers Template

Type (Contact Thermometers) RTD
Types RTD/Thermocouples Accepted PT100 RTD 
Temperature Range of Probe Accepted 850 C (1562 F)
Number of Probe Inputs/Channels 2
Resolution (thermometers) 0.1°F (0.1°C) from 148 to 1562°F (-99.9 to 850°C); 1°F (1°C) outside range

Dataloggers / Data Acquisition/Dataloggers for Environmental Variables/Temperature Dataloggers Templ

Accuracy ±1.5°F (0.8°C) from -148 to 392°F (-99.9 to 199.9°C); ±2°F (1°C) ±0.5% of reading outside range

Test Equipment General Attributes

Data Logging Yes
Calibration Included NIST Calibration
Battery Type 9v
Power Supply Voltage Battery Powered