Descripción
The Fluke 113 Utility Electrical Multimeter is an affordable addition to your toolset for basic electrical testing. With True-rms, you can be confident in the accuracy of your ac measurements. The 113 is safety rated at CAT III 600 V and Category IV 300 V and has been drop tested to 1 meter per IEC 61010-1-2001. A 9 Volt alkaline battery powers the meter for an average of 300 hours, without backlight, so you won’t need to worry about losing power. The ability to test for voltage or continuity at the same time using the VCHEK LoZ function makes the 113 a welcome addition to your tool belt.
True-rms Utility Multimeter designed for basic electrical tests.
The Fluke 113 Utility Multimeter gives utility users the means to quickly and easily do basic meter set and reconnect testing. This meter is simple-to-use and has the features needed to repair most electrical problems. The Fluke 113 has significant improvements over Fluke’s original 7-600, and other utility multimeters. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. The Fluke 113 can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this new meter is a must have for the utility users toolbox.
Manufacturer Specs
| VCHECK 1,2 | Range | 6.000 V |
| 60.00 V | ||
| 600.0 V | ||
| Resolution | 0.001 V | |
| 0.01 V | ||
| 0.1 V | ||
| Accuracy | DC, 45 to 500 Hz: 2.0 % + 3 | |
| 500 Hz to 1 kHz: 4.0 % + 3 | ||
| Diode test 3 | Range | 2.000 V |
| Resolution | 0.001 V | |
| Accuracy | 2.0 % + 3 | |
| Continuity 3 | Range | |
| Resolution | ||
| Accuracy | Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 µs or longer | |
| Ω 3 | Range | 600.0 Ω |
| 6.000 kΩ | ||
| 60.00 kΩ | ||
| Resolution | 0.1 Ω | |
| 0.001 kΩ | ||
| 0.01 kΩ | ||
| Accuracy | 0.9 % + 2 | |
| 0.9 % + 1 | ||
| 0.9 % + 1 | ||
| Capacitance 3 | Range | 1000 nF |
| 10.00 µF | ||
| 100.0 µF | ||
| 9999 µF | ||
| Resolution | 1 nF | |
| 0.01 µF | ||
| 0.1 µF | ||
| 1 µF | ||
| Accuracy | 1.9 % + 2 | |
| 1.9 % + 2 | ||
| 1.9 % + 2 | ||
| 100 µF – 1000 µF: 1.9 % + 2 | ||
| > 1000 µF: 5 % + 20 | ||
| Notes | ||
| 1 All VChek voltage ranges are specified from 60 counts to 100 % of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. 2 Crest factor of = 3 at 4000 counts, decreasing linearly to 1.5 at full scale. 3 After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity. |
||
| Maximum voltage between any terminal and earth ground | 600 V |
| Display | 3 3/4-digits, 6000 counts, updates 4/sec |
| Operating temperature | -10 °C to 50 °C (14 °F to 122 °F) |
| Storage temperature | -40 °C to 60 °C (-22 °F to 140 °F) |
| Temperature coefficient | 0.1 x (specified accuracy)/°C (< 18 °C or > 28 °C) |
| Operating altitude | 2,000 m |
| Storage altitude | 10,000 m |
| Relative humidity | 95 % to 30 °C 75 % to 40 °C 45 % to 50 °C |
| Battery type | 9 Volt Alkaline, ANSI 1604A / IEC 6F22 |
| Battery life | Alkaline: 300 hours typical, without backlight |
| Shock | 1 Meter drop per IEC 61010-1-2001 |
| Vibration | Per MIL-PRF-28800 for Class 2 instrument |
| Size (H x W x L) | 167.1 mm X 85.1 mm X 46.0 mm (6.58 in X 3.35 in X 1.81 in) |
| Weight | 13.0 oz (404 g) |
| Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1 |
| EMI regulations | Complies with FCC Part 15, Class B |
| VCHECK | Input Impedance (Nominal) | ~3 kΩ < 300 pF |
| VCHECK | Common Mode Rejection Ratio (1 kΩ Unbalanced) | > 60 dB at dc, 50 or 60 Hz |
| Ω | Open Circuit Test Voltage | < 2.7 V dc |
| Full Scale Voltage | < 0.7 V dc | |
| Diode test | Open Circuit Test Voltage | < 2.7 V dc |
| Full Scale Voltage | 2.000 V dc | |
| Ω | Short Circuit Current | < 350 µA |
| Diode test | Short Circuit Current | < 1.0 mA |
Tech Specs
Multimeters Template |
|
|---|---|
| Style | Hand-Held |
| Measures AC V | Yes |
| Measures DC V | Yes |
| Measures AC A | No |
| Measures DC A | No |
| True RMS | Yes |
| Maximum Voltage AC | 600 V |
| Resolution AC Volts | 0.1 V (100 mV) |
| # Digit Display | 3.75 |
| Counts | 6000 . |
| Backlight | Yes |
| Manual/Autoranging | Both |
| Decibels | No |
| Resistance | Yes |
| Frequency | No |
| Capacitance | Yes |
| Temperature | No |
| Diode Testing | Yes |
| CAT Rating | III |
| CAT Voltage | 300 V, 600 V |
| Intrinsically Safe | No |
| Peak Hold | No |
| Overload Protector | No |
| Kelvin 4-Wire Measurement Capability | No |
| Wireless Display | No |
| Data Hold | Yes |
| Low-Pass Filter | No |
Test Equipment General Attributes |
|
| Unique Features | VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity Record signal fluctuations using the Min/Max function Integral holster with probe holders for easy storage The optional TPAK magnetic hanger allows the user hands-free flexibility |
| Warranty | 3 YEARS |
| Safety Approval | CSA, UL |
| Interfaces I/O | Analog Output, Analog Input |
| Product Weight | 0.82 LBS |
| Product Height | 1.629 IN |
| Product Length | 10.905 IN |
| Product Width | 3.464 IN |
| Shipping Weight | 2 LBS |
| Data Logging | No |
| HTS/Schedule B Number | 9030.31.0000 |
| ECCN Number | 3A992 |
| Calibration Included | None |
| Battery Type | 9v |
| Power Supply Voltage | Battery Powered |
| Country of Origin | Singapore |
| Shipping Height | 5.91 IN |
| UPC | 095969434522 |
| Shipping Length | 12.99 IN |
| Shipping Width | 11.02 IN |




Valoraciones