Descripción
Laboratory accuracy. Wherever you go.
The Fluke 50 Series II contact thermometers offer fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged, handheld test tool. Take contact temperature for checking motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, E, N, R, and S type thermocouple (temperature sensors).
Manufacturer Specs
| Measurement accuracy | Above -100 °C (-148 °F) | J, K, T, E, and N-type: ±[0.05% + 0.3°C (0.5°F)]* R and S-type: ±[0.05% + 0.4°C (0.7°F)]* |
| Below -100 °C (-148 °F) | J, K, E, and N-types: ±[0.20% + 0.3°C (0.5°F)]* T-type: ±[0.50% + 0.3°C (0.5°F)] |
|
| Display resolution | 0.1°C / °F / K < 1000° 1°C / °F / K ³ 1000° |
|
| Measurement range | J-type | -210°C to 1200°C (-346°F to 2192°F) |
| K-type | -200°C to 1372°C (-328°F to 2501°F) | |
| T-type | -250°C to 400°C (-418°F to 752°F) | |
| E-type | -150°C to 1000°C (-238°F to 1832°F) | |
| N-type | -200°C to 1300°C (-328°F to 2372°F)* | |
| R and S-type | 0°C to 1767°C (32°F to 3212°F)* | |
| Temperature scale | ITS-90 | |
| Applicable standards | NIST-175 | |
| Environmental | Operating temperature | -10°C to 50°C (14°F to 122°F) |
| Storage temperature | -40°C to 60°C (-40°F to 140°F) | |
| Humidity | 0% to 90%; 0°C to 35°C (32°F to 95°F) 0% to 70%; 0°C to 50°C (32°F to 122°F) |
|
| General | Unit weight | 400g (14 oz) |
| Dimensions | 17.3 cm L x 8.6 cm W x 3.8 cm D (6.8 in L x 3.4 in W x 1.5 in D) | |
| Battery | 3 AA batteries; typical 1000-hour life | |
| Certification | CE, CSA, TÜV (pending) | |
| Safety | CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 | |
| * Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type thermocouples.
NSN #6685-01-292-2787 |
||
Tech Specs
Thermometers/Contact Thermometers Template |
|
|---|---|
| Type (Contact Thermometers) | Thermocouple |
| Types RTD/Thermocouples Accepted | E, J, K, T |
| Number of Probe Inputs/Channels | 1 |
| Resolution (thermometers) | 0.1 °C, 0.1 K < 1000 1°C, 1 K >=1000 |
| Accuracy | Above -100 °C: J, K, T, E, and N-type: ±[0.05% + 0.3°C]* R and S-type: ±[0.05% + 0.4°C]* Below -100 °C: J, K, E, and N-types: ±[0.20% + 0.3°C]* |
| Differential Temperature | No |
| Food Safe | No |
Test Equipment General Attributes |
|
| Warranty | 3 YEARS |
| Safety Approval | CSA |
| Product Weight | 400 GRAMS (0.882 LBS) |
| Product Height | 38 MM (1.50 IN) |
| Product Length | 173 MM (6.81 IN) |
| Product Width | 86 MM (3.39 IN) |
| Data Logging | No |
| HTS/Schedule B Number | 9025.19.8085 |
| ECCN Number | EAR99 |
| Power Supply Voltage | Battery Powered |
| Country of Origin | China |
| Shipping Height | 2.55 IN |
| Shipping Length | 9.50 IN |
| Shipping Width | 6.50 IN |




Valoraciones
No hay valoraciones aún.