Descripción
Fluke 568 EX/ETL IR Thermometer

- Intrinsically safe infrared and contact thermometer
- Meets intrinsically safe certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments
- Measures temperatures from -40°C to 800°C (-40°F to 1472°F)
- Comes with a conductive case to safely carry the IR thermometer into hazardous areas
- Offers a distance-to-spot ratio of 50:1
The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil & gas, or pharmaceutical environments, the new 568 Ex allows you to carry the most trusted name in test tools into most Ex rated areas all around the globe.
With a straight-forward user interface and soft- key menus, the Fluke 568 Ex makes even complex measurements easy. Quickly navigate and adjust emissivity, save data or turn on and off alarms, with just a few pushes of a button. All in a single intrinsically safe tool certified by major rating bodies from around the world.
Product Highlights
With a rugged, easy-to-use, ergonomic design, the Fluke 568 Ex can stand up to tough industrial, electrical, and mechanical environments.
- Meets intrinsically safe certifications in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments from recognized safety agencies around the world
- Measure -40 °C to 800 °C (-40 °F to 1472 °F)
- Conductive Case for carrying the IR thermometer safely into hazardous area
- Easily access advanced features with the soft-key buttons and graphical display
- Measure small objects from further away, with a distance-to-spot ratio of 50:1
- Compatible with mini-connector K-type thermo- couple (KTC) probe
- Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table
- Capture up to 99 points of data
- Confidently troubleshoot equipment with ± 1 % measurement accuracy
- Versatile interface with five languages from which to choose
- Two-year warranty
Manufacturer Specs
| Specifications | |
| Infrared temperature range | -40 °C to 800 °C (-40 °F to 1472 °F) |
| Infrared accuracy | < 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) ± 0.1°/1 °C or °F); = 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater |
| Display resolution | 0.1 °C/0.1 °F |
| Infrared spectral response | 8 µm to 14 µm |
| Infrared response time | < 500 ms |
| Thermocouple Type-K input temperature range | -270 °C to 1372 °C (-454 °F to 2501 °F) |
| Thermocouple Type-K input accuracy | <-40 °C: ±(1 °C + 0.2 °/1 °C) =-40 °C: ±1 % or 1 °C, whichever is greater <-40 °F: ±(2 °F + 0.2 °/1°F) =-40 °F: ±1 % or 2 °F, whichever is greater |
| D:S (distance to measurement spot size) | 50:1 |
| Laser sighting | Single-point laser |
| Minimum spot size | 19 mm (0.75 in) |
| Emissivity adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 |
| Data storage | 99 points |
| Hi/Low alarms | Audible and two-color visual |
| Min/Max/Avg/Dif | Yes |
| Display | Dot matrix with function menus |
| Backlight | Two levels, normal and extra bright for darker environments |
| Trigger lock | Yes |
| Switchable Celsius and Fahrenheit | Yes |
| Power | 2 AAA/LR03 type-approved Batteries (For a list of type-approved batteries, refer to Product Safety Instructions) |
| Battery life | 4 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle |
| Operating temperature | 0 °C to 50 °C (32 °F to 122 °F) |
| Storage temperature | -20 °C to 60 °C (-40 °F to 140 °F) |
| Bead thermocouple Type-K range | -40 °C to 260 °C (-40 °F to 500 °F) |
| Bead thermocouple Type-K accuracy | ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F), typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F) |
Tech Specs
Thermometers/IR Thermometers Template |
|
|---|---|
| IR Temperature Max | 1472 F |
| IR Temperature Min | -40 F |
| Field View Ratio (Spot Ratio) | 50:1 |
| Accuracy | <0 °C: ±(1.0 °C + 0.1 °/1 °C) ≥0 °C: ±1 % or ± 1.0 °C, whichever is greater <32 °F: ±2 °F ±0.1 °/1 °F ≥32 °F: ±1 % or ±2 °F, whichever is greater |
| Laser Pointer | Yes |
| Backlight | Yes |
| Emissivity Adjustable | Yes |
| Alarm | Yes |
| Data Hold | Yes |
| Max./Min. | Yes |
| Memory Recall | Yes |
| Thermocouple Input | Yes |
Test Equipment General Attributes |
|
| Unique Features | Meets intrinsically safe certifications in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments from recognized safety agencies around the world. Measure -40 °C to 800 °C /-40 °F to 1472 °F. Conductive Case for carrying the IR thermometer safely into hazardous area. Easily access advanced features with the soft-key buttons and graphical display. Measure small objects from further away, with a distance-to-spot ratio of 50:1. Compatible with mini-connector K-type thermocouple (KTC) probe. Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table. Capture up to 99 points of data. Confidently troubleshoot equipment with ± 1 % measurement accuracy. Versatile interface with five languages from which to choose. Two-year warranty. |
| Warranty | 2 YEARS |
| Safety Approval | CE |
| Product Weight | 2.35 LBS |
| Product Height | 2.72 CM (1.07 IN) |
| Product Length | 9.92 CM (3.91 IN) |
| Product Width | 7.56 CM (2.98 IN) |
| Shipping Weight | 2.35 LBS |
| Data Logging | No |
| Calibration Included | None |
| Battery Type | AA |
| Power Supply Voltage | Battery Powered |
| Country of Origin | China |
| Shipping Height | 3.15 IN |
| UPC | 095969666121 |
| Shipping Length | 9.84 IN |
| Shipping Width | 7.87 IN |




Valoraciones