Descripción
Fluke 721-1610 Dual Sensor Pressure Calibrator, 16 PSIG, 1000 PSIG
Pressure calibration and temperature measurement for custody transfer applications
The Fluke 721 Precision Pressure Calibrator with dual isolated pressure sensors is the ideal tool for gas custody transfer applications allowing you to take simultaneous static and differential pressure measurements with a single tool.
The 721 can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).
Manufacturer Specs
| Low pressure sensor | High pressure sensor | ||||||
| Model | Description | Range sensor 1 | Resolution sensor 1 | Accuracy sensor 1 | Range sensor 2 | Resolution sensor 2 | Accuracy sensor 2 |
| Fluke 721-1601 | Dual Sensor Pressure Calibrator, 16 PSIG, 100 PSIG | -14 psi to +16 psi -0.97 bar to 1.1 bar |
0.001 psi, 0.0001 bar |
0.025 % of full scale | -12 psi to +100 psi -0.83 bar to 6.9 bar |
0.01 psi 0.0001 bar |
0.025 % of full scale |
| Fluke 721-1603 | Dual Sensor Pressure Calibrator, 16 PSIG, 300 PSIG | -12 psi to +300 psi -0.83 bar to 20 bar |
0.01 psi 0.001 bar |
||||
| Fluke 721-1605 | Dual Sensor Pressure Calibrator, 16 PSIG, 500 PSIG | -12 psi to +500 psi -0.83 bar to 34.5 bar |
0.01 psi 0.001 bar |
||||
| Fluke 721-1610 | Dual Sensor Pressure Calibrator, 16 PSIG, 1000 PSIG | 0 psi to +1000 psi 0.00 bar to 69 bar |
0.1 psi 0.001 bar |
||||
| Fluke 721-1615 | Dual Sensor Pressure Calibrator, 16 PSIG, 1500 PSIG | 0 psi to +1500 psi 0.00 bar to 103.4 bar |
0.1 psi 0.001 bar |
||||
| Fluke 721-1630 | Dual Sensor Pressure Calibrator, 16 PSIG, 3000 PSIG | 0 psi to +3000 psi 0.00 bar to 200 bar |
0.1 psi 0.01 bar |
||||
| Fluke 721-1650 | Dual Sensor Pressure Calibrator, 16 PSIG, 5000 PSIG | 0 psi to +5000 psi 0.00 bar to 345 bar |
0.1 psi 0.01 bar |
0.035 % of full scale | |||
| Fluke 721-3601 | Dual Sensor Pressure Calibrator, 36 PSIG, 100 PSIG | -14 psi to +36 psi -0.97 bar to 2.48 bar |
-12 to +100 psi -0.83 bar to 6.9 bar |
.01 psi 0.0001 bar |
0.025 % of full scale | ||
| Fluke 721-3603 | Dual Sensor Pressure Calibrator, 36 PSIG, 300 PSIG | -12 psi to +300 psi -0.83 bar to 20 bar |
0.01 psi 0.001 bar |
||||
| Fluke 721-3605 | Dual Sensor Pressure Calibrator, 36 PSIG, 500 PSIG | -12 psi to +500 psi -0.83 bar to 34.5 bar |
0.01 psi 0.001 bar |
||||
| Fluke 721-3610 | Dual Sensor Pressure Calibrator, 36 PSIG, 1000 PSIG | 0 psi to +1000 psi 0.00 bar to 69 bar |
0.1 psi 0.001 bar |
||||
| Fluke 721-3615 | Dual Sensor Pressure Calibrator, 36 PSIG, 1500 PSIG | 0 psi to +1500 psi 0.00 bar to 103.4 bar |
0.1 psi 0.01 bar |
||||
| Fluke 721-3630 | Dual Sensor Pressure Calibrator, 36 PSIG, 3000 PSIG | 0 psi to +3000 psi 0.00 bar to 200 bar |
0.1 psi 0.01 bar |
||||
| Fluke 721-3650 | Dual Sensor Pressure Calibrator, 36 PSIG, 5000 PSIG | 0 psi to +5000 psi 0.00 bar to 345 bar |
0.1 psi 0.01 bar |
0.035 % of full scale | |||
| General specifications | |
| Instrument setup recall | Last used on power-up |
| Environmental | Operating temperature -10 °C to +50 °C Storage temperature (without batteries) -20 °C to +60 °C |
| Altitude | 2,000 meters |
| Ingress protection | IP-40 |
| Power requirements | 6.0 v dc |
| Battery life | >35 hours, typical usage |
| Batteries required | (4) Standard AA cells |
| Dimentions (HxWxD) | 7.9” X 4.3” X 2.3” (20 cm X 11 cm X 5.8 cm) |
| Weight | 03539 kg (1 lb 3 oz) |
| Connectors/ports pressure | Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe |
| Electrical and temperature measurement 1-year | |||
| Function | Range | Resolution | Accuracy |
| mA measure | 0 to 24 mA | 0.001 mA | ±0.015% of rdg ±0.002mA |
| VDC measure | 0 to 30 VDC | 0.001V | ±0.015% of rdg ±0.002V |
| *Temperature measure (RTD/Ohms) | -40 °C to 150 °C (-40 °F to 302 °F) |
0.01 °C, 0.01 °F | ±0.015% of rdg ±0.02 ohms; ±0.1°C (±0.2°F) ±0.25 °C (±0.45 °F) combined uncertainty when using 720 RTD probe accessory |
| Loop power supply | 24V | N/A | 24 mA @ 24V |
| *Temperature measurement requires optional Fluke-720RTD Pt-100 RTD probe available as an accessory | |||
| Temperature effect | |||
| No effect on accuracy on all functions from 15 °C to 35 °C | |||
| Add ± 0.002 % F.S./°C for temps outside of 15 °C to 35 °C | |||
Tech Specs
Process / Calibration/Pressure Calibration/Pressure Calibrators Template |
|
|---|---|
| Max Pressure | 1000 psi (1000 hPa) |
| Accuracy | Sensor 1: 0.025 % of full scale
Sensor 2: 0.025 % of full scale |
| Maximum Resolution | 0.001 psi |
| Absolute Pressure | Yes |
| Gauge Pressure | No |
| Differential Pressure | Yes |
| Built in Pressue Pump | No |
| Intrinsically Safe | No |
| Min/Max | Yes |
| Simulate Loop Voltage | Yes |
| Modular Inputs Available | Yes |
| Hart Compatible | Yes |
| Battery Run Time | 35 HR |
| FieldBus Compatible | No |
| Backlight | Yes |
| Source/Simulate DC Current | No |
| Measure DC Current | No |
Test Equipment General Attributes |
|
| Unique Features | • Ideal for gas flow calibration
(custody transfer) applications • Two isolated, stainless steel, pressure sensors with 0.025 % accuracy • Pt100 RTD input for temperature measurement, (probe optional) • Measures 4 to 20 mA signals • Internal 24 V loop power supply can power a transmitter under test • Measure up to 30 V dc, check 24 V loop power supplies • Extend pressure measurement range with connection to external 700 series pressure modules (29 ranges) • Large backlit graphic display can display up to three inputs simultaneously • Store five instrument setups for recall and use |
| Warranty | 3 YEARS |
| Additional Info/Comments | Includes:
◦Dual Sensor Pressure Calibrator, 16 PSIG, 1000 PSIG ◦Soft case ◦Four (4) AA batteries ◦Manual ◦Traceable calibration certificate ◦Test leads |
| Interfaces I/O | Analog Output, Other, Analog Input |
| IP Rating | IP40 |
| Product Weight | 1.19 LBS |
| Product Height | 2.3 IN |
| Product Length | 7.9 IN |
| Product Width | 4.3 IN |
| Shipping Weight | 4.13 LBS |
| Data Logging | No |
| ECCN Number | EAR99 |
| Calibration Included | NIST Calibration |
| Battery Type | AA |
| Power Supply Voltage | Battery Powered |
| Country of Origin | China |
| Shipping Height | 5.51 IN |
| UPC | 095969673945 |
| Shipping Length | 12.6 IN |
| Shipping Width | 10.63 IN |




Valoraciones