Dataloggers
Mostrando 235–243 de 1087 resultadosOrdenado por los últimos
-
Dataloggers
Data Logger Digilent 6069-471-001 – High-Precision Thermocouple Measurement USB/Ethernet System (TC-32 and TC-32-EXP)
MCC TC-32 and TC-32-EXP expansion module (64 thermocouple inputs and 80 digital I/O)
- TC-32 and TC-32-EXP: 64 thermocouple inputs and 80 digital I/O
- 24-bit resolution
- 3 S/s/ch sample rate
- Supports thermocouple types J, K, R, S, T, N, E, and B
- 40 digital I/O (80 digital I/O when using TC-32-EXP)
- USB and Ethernet interfaces.
(0 reviews) -
Dataloggers
Escáner de Temperatura Fluke 1586A/DSHC 120/C Super-DAQ Precision Temperature Scanner, 1 INT/1 EXT MODULE, 120V, Accredited Calibration
SUPER-DAQ, 1 INT/1 EXT MODULE, 120V, ACCREDITED CAL
- 1586A/DSHC 120/C Super-DAQ Precision Temperature Scanner
- 1 INT/1 EXT MODULE
- 120V
- Accredited Calibration
- Best-in-class temperature measurement accuracy
- PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
- Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ± 0.002 °C
- Input channels: Up to 40 isolated universal inputs
- Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
- 6 1/2 digit display resolution for dc voltage, dc current, and resistance
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
- Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
- Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
- Data security: Administrator and user profiles for protecting settings and ensuring test traceability
- Mx + B scaling and channel offset zero function
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded.
(0 reviews) -
Dataloggers
Escáner de Temperatura Fluke 1586A/DSHC 120 Super-DAQ Precision Temperature Scanner, 1 INT/1 EXT MODULE, 120V
SUPER-DAQ, 1 INT/1 EXT MODULE, 120 V
- 1586A/DS-HC 120 Super-DAQ Precision Temperature Scanner
- 1 INT/1 EXT MODULE
- 120V
- Best-in-class temperature measurement accuracy
- PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
- Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ± 0.002 °C
- Input channels: Up to 40 isolated universal inputs
- Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
- 6 1/2 digit display resolution for dc voltage, dc current, and resistance
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded.
- Mx + B scaling and channel offset zero function
- Data security: Administrator and user profiles for protecting settings and ensuring test traceability
- Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
- Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
(0 reviews) -
Dataloggers
Escáner de Temperatura Fluke 1586A/2HC 120/C Super-DAQ Precision Temperature Scanner, 2 Hi-Capacity Modules, 100V, Accredited Calibration
SUPER-DAQ, 2 HI-CAPACITY MODULES, 120V, ACCREDITED CAL
- 1586A/2HC 120/C Super-DAQ Precision Temperature Scanner
- 2 Hi-Capacity Modules
- 100V
- Accredited Calibration
- Best-in-class temperature measurement accuracy
- PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
- Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ± 0.002 °C
- Input channels: Up to 40 isolated universal inputs
- Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
- 6 1/2 digit display resolution for dc voltage, dc current, and resistance
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded.
- Mx + B scaling and channel offset zero function
- Data security: Administrator and user profiles for protecting settings and ensuring test traceability
- Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
- Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
(0 reviews) -
Dataloggers
Escáner de Temperatura Fluke 1586A/2HC 120 Super-DAQ Precision Temperature Scanner, 2 Hi-Capacity Modules, 120V
SUPER-DAQ, 2 HI-CAPACITY MODULES, 120 V
- 1586A/2HC 120 Super-DAQ Precision Temperature Scanner
- 2 Hi-Capacity Modules
- 120V
- Best-in-class temperature measurement accuracy
- PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
- Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ± 0.002 °C
- Input channels: Up to 40 isolated universal inputs
- Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
- 6 1/2 digit display resolution for dc voltage, dc current, and resistance
- Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
- Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
- Data security: Administrator and user profiles for protecting settings and ensuring test traceability
- Mx + B scaling and channel offset zero function
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy.
(0 reviews) -
Dataloggers
Escáner de Temperatura Fluke 1586A/2DS 120/C Super-DAQ Precision Temperature Scanner, 2 DAQ-STAQ Modules, 120V, Accredited Calibration
SUPER-DAQ, 2 DAQ-STAQ MODULES, 120V, ACCREDITED CAL
- 1586A/2DS 120/C Super-DAQ Precision Temperature Scanner
- 2 DAQ-STAQ Modules, 120V
- Accredited Calibration
- Best-in-class temperature measurement accuracy
- PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
- Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ± 0.002 °C
- Input channels: Up to 40 isolated universal inputs
- Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
- 6 1/2 digit display resolution for dc voltage, dc current, and resistance
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
- Data security: Administrator and user profiles for protecting settings and ensuring test traceability
- Mx + B scaling and channel offset zero function
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded.
- Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
- Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
(0 reviews) -
Dataloggers
Escáner de Temperatura Fluke 1586A/2DS 120 Super-DAQ Precision Temperature Scanner, 2 DAQ-STAQ Modules, 120V
SUPER-DAQ, 2 DAQ-STAQ MODULES, 120 V
- 1586A/2DS 120 Super-DAQ Precision Temperature Scanner
- 2 DAQ-STAQ Modules
- 120V
- Best-in-class temperature measurement accuracy
- PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
- Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ± 0.002 °C
- Input channels: Up to 40 isolated universal inputs
- Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
- 6 1/2 digit display resolution for dc voltage, dc current, and resistance
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
- Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routine
- Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
- Data security: Administrator and user profiles for protecting settings and ensuring test traceability
- Mx + B scaling and channel offset zero function
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded.
(0 reviews) -
Dataloggers
Escáner de temperatura Fluke 1586A/1HC 120/C Super-DAQ Precision Temperature Scanner, 1 Hi-Capacity Modules, 120V, Accredited Calibration
SUPER-DAQ, 1 HI-CAPACITY MODULE, 120V, ACCREDITED CAL
- 1586A/1HC 120/C Super-DAQ Precision Temperature Scanner
- 1 Hi-Capacity Modules
- 120V
- Accredited Calibration
- Best-in-class temperature measurement accuracy
- PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
- Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ± 0.002 °C
- Input channels: Up to 40 isolated universal inputs
- Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
-
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
- Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
- Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
- Data security: Administrator and user profiles for protecting settings and ensuring test traceability
- Mx + B scaling and channel offset zero function
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded6 1/2 digit display resolution for dc voltage, dc current, and resistance.
(0 reviews) -
Dataloggers
Fluke 1586A/1HC 120 Super-DAQ Precision Temperature Scanner, 1 Hi-Capacity Modules, 120V
SUPER-DAQ, 1 HI-CAPACITY MODULE, 120 V
- 1586A/1HC 120 Super-DAQ Precision Temperature Scanner
- 1 Hi-Capacity Modules
- 120V
- Best-in-class temperature measurement accuracy
- PRTs ± 0.005 °C (using external DAQ‑STAQ Multiplexer)
- Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ± 0.002 °C
- Input channels: Up to 40 isolated universal inputs
- Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
- 6 1/2 digit display resolution for dc voltage, dc current, and resistance
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurement accuracy
- Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
- Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
- Data security: Administrator and user profiles for protecting settings and ensuring test traceability
- Mx + B scaling and channel offset zero function
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded.
(0 reviews)