Descripción
Sauermann DBM 620C – Air Flow Meter Kit
- Air Flow Meter Kit
- All hoods included
- Electronic airflow meter type DBM 620C
- Measuring ranges from 35 to 4250 m3/h, +/-2500 Pa, 0,2 to 10 m/s, 0 to 100 %RH, -20 to 70 °C.
- Removable Bluetooth pressure measuring unit
- Free SmartKapp mobile App
The Sauermann DBM 620C Air Flow Meter is a multipurpose electronic air balancing instrument primarily used for efficiently taking direct air volume readings from air vents.
The DBM 620C is supplied with base including temperature and humidity probe, pressure measuring unit, 610x610mm (2’x2′) hood including foldable frame and airflow straightener, 720x720mm (2.36’x2.36′) / 720x1320mm (2.36’x4.33′) / 420x1520mm (1.4’x 5′) / 1020x1020mm (3.35’x3.35′) hoods with foldable frames, frame rods with sheath, 2x80cm of silicone tube, calibration certificate and transport case.
Capture Hoods
The DBM 620C air flow meter comes in standard with a 2 x 2 ft (610 x 610 mm) hood. Hoods are airtight and has a transparent viewing window that allows the user to see through the vent to ensure the hood is in the proper position.
4 additional hoods:
- 3.35 x 3.35 ft (1020 x 1020 mm)
- 2.36 x 2.36 ft (720 x 720 mm)
- 2.36 x 4.33 ft (720 x 1320 mm)
- 1.38 x 4.99 ft (420 x 1520 mm)
Functions of the micromanometer housing
The electronic housing can be used alone to perform the following functions:
In air velocity and airflow:
- Choose between the Pitot tube, Debimo blades, coefficient or measurement grid Section selection
- Unit selection
- Point/point, automatic or automatic point/point average
- Manual compensation in temperature, automatic or manual compensation in atmospheric pressure
- Hold, minimum and maximum values
- Standardized airflow, K factor
In pressure:
- Manual or automatic auto-zero
- Unit selection
- Pressure integration (from 0 to 9)
- Point/point, automatic or automatic point/point average
- Hold, minimum and maximum values

Measurement grid
The measurement grid is attached to the base and measures 24 different points throughout the surface of the flow area. Measurement is performed using a differential pressure sensor calibrated in atmospheric pressure and temperature and compensated in temperature.
Autonomous micromanometer
Once removed, the measuring unit can be used as a micromanometer:
- Measure airflow in a duct using the Pitot tube attachment
- Silcone tubing allows technician to check for filter issues

Device positioning on the air vent
SmartKap mobile application will help you correctly position the hood on the air vent:
- Select the correct air vent type, OR
- Create a customized air vent if required
- Follow the instructions for a perfect fit!
Operating principles
The DBM 620C housing communicates with the smartphone or tablet via Bluetooth®. This allows measured values reading and viewing of reports directly on your mobile device screen, via the dedicated SmartKap mobile application.
DBM 620 Electronic Housing on the Base


SmartKap Mobile App
In The Box
- 1 Standard DBM 620 kit
- 4 Additional hoods:
- 1 Hood of 2.36 x 2.36 ft (720 x 720 mm) with foldable frame and transport case
- 1 Hood of 2.36 x 4.33 ft (720 x 1320 mm) with foldable frame and transport case
- 1 Hood of 1.38 x 4.99 ft (420 x 1520 mm) with foldable frame and transport case
- 1 Hood of 3.35 x 3.35 ft (1020 x 1020 mm) with foldable frame and transport case
Manufacturer Specs
| Model: DBM 620C Specifications | |
| Type | Air Flow Meter |
| Includes | 1 Standard DBM 620 kit 4 Additionnal hoods: 1 Hood of 2.36 x 2.36 ft (720 x 720 mm) with foldable frame and transport case 1 Hood of 2.36 x 4.33 ft (720 x 1320 mm) with foldable frame and transport case 1 Hood of 1.38 x 4.99 ft (420 x 1520 mm) with foldable frame and transport case 1 Hood of 3.35 x 3.35 ft (1020 x 1020 mm) with foldable frame and transport case |
| Measure Details | |
| Units | °C, % RH, Pa, m/s, hPa, mł/h |
| Measuring Ranges | |
| Airflow (calculated parameter) | Accuracy – ±3% of the measurement ±10 m3/h
Measuring range – From 35 to +4250 m3/h Resolution – 1 m3/h |
| Air velocity (calculated parameter) | Accuracy – ±3% of the measured value ±0.04m/s Measuring range – From 0.2 to 10m/s Resolution – 0.01 m/s up to 3 m/s and 0.1 m/s beyond |
| Temperature (NTC) | Accuracy – ±0.2°C
Measuring range – From -20 to 70°C Resolution – 0.1 °C |
| Relative humidity (capacitive sensor) | Accuracy -Repeatability, linearity: ±1.5%RH(2)(from 10 to 80% RH and from 10 to 50°C)(3)Hysteresis: 0.8% RH at 25°CTime drift: <0.5% RH per year in normalconditions of use (from 5 to 50°C and from20 to 80% RH, apart from indoor pollutants)
Measuring range – From 0 to 100%RH Resolution – 0.1%RH |
| Atmospheric pressure | Accuracy – ±3 hPa
Measuring range – From 700 to 1100hPa Resolution – 1 hPa |
| Pressure | Accuracy – ±0.2% of reading ±2 Pa(5)
Measuring range – From 700 to 1100hPa | From -2500 to +2500 Pa Resolution – From 0.001 to 0.1 Pa |
| Technical Details | |
| Parameters | Air velocity Airflow Humidity Temperature |
| Displays | On smartphone or tablet |
| Integrated support for smartphone or tablet | Adjustable integrated supportSmartphone or tablet max. dimensions: 10″ |
| Connectors | ABS connectors, Ø7 x 4 mm |
| Maximum service pressure | 500 mbar |
| Storage capacity | Standard size of a measurement dataset report: 1 Mo |
| Module | Shock-proof made of ABS |
| Keypad | 1 key on the module |
| Languages | German, Spanish, Italian, Dutch, Portuguese, Hungarian, Polish, Romanian, Russian, Slovak, Finnish, Danish, Norwegian, Swedish, Chinese, Korean, Japanese |
| Bluetooth | Class 1 Bluetooth® 4.2 Bluetooth® range: 2.4 GHz Range up to 30 m (98 ft) – Depending on smartphone and tablet Bluetooth® radio strength. Minimum required versions: Android 4.4, iOS 8.0, Bluetooth® 4.0 |
| Auto-shut-off | Adjustable from 0 to 60 minutes |
| IP Protection | IP 40 |
| Battery life | 30 hours |
| Power supply | 4 alkaline batteries LR6 AA 1.5V |
| Protective cover | No |
| Environmental conditions of use | Air, non corrosive and combustible gasesTemperature: from -5 to +50°C, in dry air and non-condensing condition Hygrometry: in non-condensing conditions (< 80% RH)Maximum altitude: 2000 m |
| European Union directives | 2011/65/EU RoHS II; 2012/19/EU WEEE; 2014/53/EU RED |
| Instrument Dimensions | |
| Length | 475 mm |
| Width | 455 mm |
| Height | 255 mm |
| Weight | 2900 g |
| Operating Temperature | |
| Min | 0.00 °C |
| Max | 50.00 °C |
| Storage Temperature | |
| Min | -20.00 °C |
| Max | 60.00 °C |