Description

Comet T3111
- T3111 Temperature and Humidity, Cable Probe (1m) Output 4-20mA
- Relative humidity, temperature sensors at probe on the cable
- Programmable temperature and humidity transmitter is equipped with temperature and relative humidity sensors
- Computerized design ensures temperature compensation of the humidity sensor and fails indication
- Humidity transmitters are equipped with two galvanic isolated 4-20mA outputs
Temperature and Humidity, Cable Probe, Cable 1m
Humidity, temperature transmitter. Outdoor, indoor use. Relative humidity, temperature sensors at probe on the cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. The device is supplied with a T+RH probe with 1m cable. Cable lengths 2m or 4m are available optionally.
Programmable temperature and humidity transmitter is equipped with temperature and relative humidity sensors. Measured values are also converted to other humidity interpretation – dew point temperature, absolute humidity, specific humidity, mixing ratio, or specific enthalpy. Degrees Celsius and Fahrenheit are user selectable. Transmitter contains a microprocessor-based control circuitry in a durable plastic case with connection terminals and sensors in a probe on a cable. Sensors are protected with a filter with stainless steel mesh. Humidity transmitters is equipped with two galvanic isolated 4-20mA outputs. Configuration of outputs and output range are user adjustable. Large dual line LCD for simultaneous display of T+RH or other humidity interpretation is an advantage. Display is possible to switch off. Computerized design ensures temperature compensation of the humidity sensor and fails indication. State-of-the-art capacitive polymer sensor ensures excellent calibration long-term stability, inertia against water, and condensation. Transmitters are designed for use in non-aggressive environment.
Applications – Measuring and control of air humidity at:
- Building HVAC management
- Building HVAC automation
- Warehouses
- Glasshouses
- Manufacturers
- Museums, archives, galleries
- Air-conditioned rooms
- Weather stations
Outputs are set to maximum range from the manufacturer (-30 to +105°C, 0 to 100%RH). Free configuration program TSensor for transmitter adjustment is ready to download anytime. If different adjustment of outputs is required, please specify required output values (RH, T, Tdp, ..) and required ranges in the order. Adjustment is free of charge. Any measured value – temperature, relative humidity, dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy can be assigned to each output of the transmitter. Also identical value can be assigned to both outputs.

Typical Application Wiring of Dual Output Transmitter
Ordering Example: Transmitter T3111, output 1: RH 10 to 90%, output 2: temperature 0 to 35°C

Figure: Relative humidity operating range
Manufacturer Specs
| Comet T3111 Specifications | |
| Technical parameters | Value |
| Output | 4-20mA |
| Measured Value | Temperature + Relative Humidity |
| Construction Type | With T+RH Probe on Cable |
| Design | Industrial |
| Temperature Measuring Range | -30 to 105 °C |
| Relay Output | No |
| Two-State Input | No |
| Lcd Display | Yes |
| PoE | No |
| Relative humidity range | 0 to 100% |
| Accuracy of relative humidity measurement | ±2.5% relative humidity from 5 to 95% at 23°C |
| Accuracy of temperature output | ±0.4°C from -30 to +100°C ±0.4% from reading over +100°C |
| Available temperature units | degrees Celsius, Fahrenheit |
| Accuracy and range of dew point temperature output – for more details see graphs | ±1.5°C at ambient temperature T<25°C and RH>30% range -60 to +80 °C |
| Accuracy and range of absolute humidity output | ±1.5g/m3 at ambient temperature T < 25°C range 0 to 400 g/m3 |
| Accuracy and range of specific humidity output | ±2g/kg at ambient temperature T < 35°C range 0 to 550 g/kg |
| Accuracy and range of mixing ratio output | ±2g/kg at ambient temperature T < 35°C range 0 to 995 g/kg |
| Accuracy and range of specific enthalpy output | ±3kJ/kg at ambient temperature T < 25°C range: 0 to 995 kJ/kg |
| Temperature operating range of case with electronics | -30 to +80°C |
| Temperature operating range of LCD display | readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C |
| Range of humidity sensor temperature compensation | all temperature range |
| Current outputs – two-wire connection | 4-20mA, galvanic isolated |
| Configuration of outputs and output range | user adjustable from the PC |
| Filtering ability of sensor cover | 0.025mm – filter with stainless steel mesh |
| Protection of the case with electronics | IP65 electronics, IP40 sensors |
| Power | 9-30Vdc |
| Length of the probe cable | 1m, 2m or 4m optionally |
| Dimensions | display unit 88.5 x 114 x 39.5 mm (W x H x D), probe length 88 mm, probe diameter 18mm |
| Weight | approximately 210g – 1m probe |
| Warranty | 3 years |
Tech Specs
Dataloggers / Data Acquisition/Dataloggers for Environmental Variables/Temperature Dataloggers Templ |
|
|---|---|
| Max Temperature | 105 C |
| Min Temperature | -30 C (-22 F) |
| LCD Screen | No |
| Software Included | Yes |
Test Equipment General Attributes |
|
| Warranty | 3 YEARS |
| Product Weight | 0.5 LBS |
| Shipping Weight | 0.6 LBS |
| HTS/Schedule B Number | 9025.19.8080 |
| ECCN Number | EAR99 |
| Country of Origin | Czech Republic |