Descripción
Madgetech VFC2000 w/o Bottle – Low-Cost Vaccine Temperature Monitoring System

- No glycol included
- Records temperatures as low as -100 °C (-148 °F)
- Includes ISO17025 accredited calibration certificate
- VFC & CDC Compliant
- Audible & Visual Alarms
The VFC2000 is a simple, low-cost solution for vaccine temperature monitoring compliance. The VFC2000 is designed to satisfy all CDC and VFC requirements. The VFC2000 also provides precise, continuous temperature monitoring and validation for temperatures as low as -100 °C (-148 °F).
Featuring a convenient LCD screen, the VFC2000 displays current, minimum, and maximum readings as well as a battery level indicator. The VFC2000 is also equipped with an LED reminder to conduct the required 24-hour temperature check. If temperatures fluctuate out-of-range, the VFC2000 triggers an audio and visual alert.
The VFC2000 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical and tabular data is provided for analysis and can be viewed using the software which supports customizable engineering units.
Manufacturer Specs
| Memory | 16,128 readings (all channels enabled) |
| Reading Rate | 1 reading every second up to 1 reading every 24 hours |
| Cold Junction Compensation | Automatic based on internal channel |
| Battery Life | 3 years typical at 1 minute reading rate |
| Material | ABS Plastic |
| Dimensions | 3.0 in x 3.5 in x 0.95 in (76.2 mm x 88.9 mm x 24.1 mm) – Data logger only |
| Operating Environment | -20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing |
| Required Interface Package | USB to Mini USB Cable |
| Weight | 1.1250 LBS |
| Baud Rate | 250,000 |
| Temperature | |
| Internal Channel Temperature Sensor | Semiconductor |
| Internal Channel Temperature Range | -20 °C to 60 °C (-4 °F to +140 °F) |
| Internal Channel Temperature Resolution | 0.01 °C (0.18 °F) |
| Internal Channel Temperature Calibrated Accuracy | ±0.5 °C (0 °C to +50 °C) |
| Remote Channel Temperature Sensor | Type K Thermocouple (Included) |
| Remote Channel (Thermocouple) Temperature Range | -100 °C to +80 °C (-148 °F to +176 °F) |
| Remote Channel (Glycol Bottle) Temperature Range | -50 °C to +80 °C (-58 °F to +176 °F) |
| Remote Channel Temperature Resolution | 0.1 °C (0.18 °F) |
| Remote Channel Temperature Calibrated Accuracy | ±0.5 °C |
Tech Specs
Dataloggers / Data Acquisition/Dataloggers for Environmental Variables/Temperature Dataloggers Templ |
|
|---|---|
| Type | Other |
| Max Temperature | 140 F (60 C) |
| Min Temperature | -4 F |
| Power Source | Battery |
| Battery Life | 3 YEARS (26280 HR) |
| Input Source | External Probe |
| Accuracy | ±0.5 °C (0 °C to +50 °C) |
| LCD Screen | Yes |
Test Equipment General Attributes |
|
| Product Weight | 1.1250 LBS |
| Product Height | 3 IN |
| Product Length | 3.5 IN |
| Product Width | 0.95 IN |
| Shipping Weight | 1.28 LBS |
| Country of Origin | United States |




Valoraciones