The Fluke 64 MAX, 62 MAX+ and 62 MAX IR Thermometers have the precision you need to do your job accurately and will not break the budget. Designed and tested to survive a 3 meter drop, you can count on these lightweight, compact infrared thermometers to work when you need them to work–even in the harshest environments and when you’re not able to be there (64 MAX).

Temperature Range
64 MAX
-30 °C to 600 °C (-22 °F to 1112 °F)
62 MAX+
-30 °C to 650 °C (-22 °F to 1202 °F)
62 MAX
-30 °C to 500 °C (-22 °F to 932 °F)
Temperature Accuracy
64 MAX
± 1.0 °C or ± 1.0 % of reading, whichever is greater ± 2.0 °C at -10 °C to 0 °C, ± 3.0 °C at -30 °C to -10 °C
62 MAX+
± 1.0 °C or ± 1.0 % of reading, whichever is greater ± 2.0 °C at -10 °C to 0 °C, ± 3.0 °C at -30 °C to -10 °C
62 MAX
± 1.5 °C or ± 1.5 % of reading, whichever is greater ± 2.0 °C at -10 °C to 0 °C, ± 3.0 °C at -30 °C to -10 °C
Distance:Spot
64 MAX
20:1
62 MAX+
12:1
62 MAX
10:1
Internal Memory
64 MAX
99 data point logging
Auto Capture
64 MAX
- Precise laser technology for more accurate and repeatable measurements
- Temperature accuracy of up to ≥ 0 °C: ± 1 °C or ± 1 % of reading whichever is greater with 20:1 distance to spot ratio (64 MAX)
- Flashlight (64 MAX) and large, easy-to-read backlit LCD display for easy viewing even in dark environment
- IP54 rated for extra protection against airborne contaminants
- Get your tool to work when you can’t–set time and desired interval between measurements and Auto Capture will capture spot tem- peratures unattended (64 MAX)
- 99 data point logging (64 MAX)
- Displays the minimum, maximum or average temperature, or the difference between two measurements
- Hi and Lo alarms for rapid display of measurements outside set limits
- The 62 MAX+ has dual rotating lasers to help you identify area to be measured. The measurement area is the spot between the dots
- (62 MAX and 64 MAX have 1).
- Small and lightweight, fits easily into your tool box
Manufacturer Specs
| General Specifications | |||
| 64 MAX | 62 MAX+ | 62 MAX | |
| Key features | |||
| Temperature range | – 30 °C to 600 °C (-22 °F to 1112 °F) |
– 30 °C to 650 °C (-22 °F to 1202 °F) |
– 30 °C to 500 °C (-22 °F to 932 °F) |
| Accuracy (Calibration geometry with ambient temperature 23 °C +/- 2 °C) | ± 1.0 °C or ± 1.0 % of reading, whichever is greater ± 2.0 °C at -10 °C to 0 °C ± 3.0 °C at -30 °C to -10 °C |
± 1.5 °C or ± 1.5 % of reading, whichever is greater ± 2.0 °C at -10 °C to 0 °C ± 3.0 °C at -30 °C to -10 °C |
|
| Optical resolution | 20:1 (calculated at 90 % energy) |
12:1 (calculated at 90 % energy) |
10:1 (calculated at 90 % energy) |
| Response time (95 %) | < 500 ms (95 % of reading) | < 300 ms (95 % of reading) | < 500 ms (95 % of reading) |
| Spectral response | 8 to 14 microns | ||
| Emissivity | 0.10 to 1.00 | ||
| Display resolution | 0.1 °C (0.2 °F) | ||
| Repeatability (% of reading) | ± 0.5 % of reading or ± 0.5 °C (whichever is greater) |
± 0.8 % of reading or
± 1 °C (whichever is greater)
|
|
| Auto Capture | Set time and interval to capture up to 99 measurements | – | |
| Internal memory | 99 data point logging capability | – | |
| Flashlight | Yes | – | |
| Power | 1 AA alkaline battery | ||
| Battery life | 30 hours with laser and backlight on | 8 hours with laser and backlight on | 10 hours with laser and backlight on |
| Weight | 255 g (8.99 oz) | ||
| Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches | ||
| Operating temperature | 0 °C to 50 °C (32 °F to 122°F) | ||
| Storage temperature | -20 °C to 60 °C (-4 °F to 140 °F) (without battery) | ||
| Operating humidity | Non- condensing @ ≤ 10 °C (50 °F) ≤ 90 % RH @ 10 °C (50 °F) to 30 °C (86 °F) ≤ 75 % RH @ 30 °C (86 °F) to 40 °C (104 °F) ≤ 45 % RH @ 40 °C (104 °F) to 50 °C (122 °F) |
||
| Operating altitude | 2000 meters above mean sea level | ||
| Storage altitude | 12,000 meters above mean sea level | ||
| Drop test | 3 meters | ||
| Implement standard | Q/ASF01 | ||
| Standards and agency approval | |||
| Compliance | IEC 61010-1: Pollution Degree 2 | ||
| Laser safety | IEC 60825-1 Class 2, 650 nm, < 1 mW | ||
| Ingress protection rating | IP 54 per IEC 60529 | ||
| Warranty | 3 years | ||
Tech Specs
Thermometers/IR Thermometers Template |
|
|---|---|
| IR Temperature Max | 1112 F |
| IR Temperature Min | -22 F |
| Field View Ratio (Spot Ratio) | 20:1 |
| Accuracy | ± 1.0 °C or ± 1.0 % of reading, whichever is greater |
| Laser Pointer | Yes |
| Backlight | Yes |
| Emissivity Adjustable | Yes |
| Alarm | Yes |
| Data Hold | Yes |
| Max./Min. | Yes |
| Memory Recall | Yes |
Test Equipment General Attributes |
|
| Warranty | 3 YEARS |
| Product Weight | 0.7 LBS |
| Product Height | 2.50 IN |
| Product Length | 10.50 IN |
| Product Width | 7.25 IN |
| Data Logging | Yes |
| HTS/Schedule B Number | 9025.19.8080 |
| ECCN Number | EAR99 |
| Battery Type | AA |
| Power Supply Voltage | Battery Powered |
| Country of Origin | China |
| Shipping Height | 2.50 IN |
| Shipping Length | 10.50 IN |
| Shipping Width | 7.25 IN |