Descripción
Lascar EL-MOTE-TH+ High Accuracy Wireless Temp & RH Data Logger
High Accuracy Wireless Temp & RH Data Logger
- Measures ambient temperature between -30 to +80 °C/-22 to +176 °F and relative humidity 0 to 100 %RH
- Records and uploads temperature and humidity data to the EasyLog Cloud
- Access live temperature and humidity data via any Internet Browser or the EasyLog Cloud App
The EL-MOTE-TH+ is a Cloud-enabled, high accuracy, wireless data logger, designed to monitor temperature and humidity in a large range of indoor and outdoor applications. EasyLog Cloud harnesses the power of IoT to automate data logging and alert notifications – perfect for both compact systems with just a few sensor requirements to corporate solutions with thousands of devices around the globe.

The EL-MOTE-TH+ kit has been designed to monitor air temperature and relative humidity in a large range of applications. Its external temperature and humidity probe made it an ideal choice for applications where it may be problematic to locate the whole device such as museum display cases and HVAC systems.
Products in the EL-MOTE range are simple to set-up and easy to use. Download the EasyLog Cloud App and set-up a device in minutes over your WiFi network. After set-up, the device can be placed anywhere within range of the WiFi network, continually monitoring and recording your data to the EasyLog Cloud. Access your data on any Internet Browser or the EasyLog Cloud App, enabling you to monitor the ambient temperature and humidity of your chosen location from anywhere at any time.
EL-MOTE devices can be programmed with high and low temperature and humidity alarm zones. If a temperature or humidity zone is breached, an alarm will be activated. Alarm options include: email alerts (which can be sent to one or multiple email addresses), beeper sound alarms, and LED flash alerts.
Manufacturer Specs
| General Specifications | ||||
| Logger Specification | ||||
| Minimum | Typical | Maximum | Unit | |
| Battery Life | 2* | years | ||
| Battery Type | 4 x 1.5V AA cells | |||
| Operating Temperature (Powered by Batteries Supplied) | -20 (-4) | +54 (129.2) | ˚C ( ˚F) | |
| Operating Temperature (Mains Adapter Powered) | -20 (-4) | +60 (140) | ˚C ( ˚F) | |
| Logging Period (User Configurable) | 10 sec | 10 min | 12 hrs | |
| Transmission Period (User Configurable) | 1 min | 1 hour | 24 hours | |
| Dimensions | 93 x 93 x 32 (3.7 x 3.7 x 1.3) | mm (inches) | ||
| IP Rating | 67 | |||
| Probe Specification | ||||
| Minimum | Typical | Maximum | Unit | |
| Temperature Range | -30 to +80 (-22 to +176) | ˚C (˚F) | ||
| Temperature Resolution | 0.1 (0.1) | ˚C (˚F) | ||
| Temperature Accuracy | ±0.3 (+5 to +60) (±0.6 (+41 to +140)) |
±0.8 (-20 to +60) (±1.6 (-4 to +140)) |
˚C (range) (˚F (range)) |
|
| Humidity Range | 0 to 100 | %RH | ||
| Humidity Resolution | 1 | %RH | ||
| Humidity Accuracy (@25˚C) | ±2** (20 to 80) | ±5** (0 to 100) | %RH (%RH) | |
| Probe Dimensions (Without Bracket) | 37 x 12 x 8 (1.5 x 0.5 x 0.3) | mm (inches) | ||
| Cable Length | 2000 (79) | mm (inches) | ||




Valoraciones