Descripción
Two essential tools in one.
Fluke introduces a new test tool category.
The Fluke 1577 and 1587 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance. Like other tools that you have come to expect from Fluke, the 1577 and 1587 are rugged, reliable, and easy to use. Whether you work on motors, generators, cables, or switch-gear, the Fluke 1577/1587 Insulation Multimeters are ideally suited to help you with your tasks.
Rely on Fluke for innovations that generate new demand
Applications:
Field service electricians, maintenance electricians and technicians, plant and process electricians – for daily troubleshooting and maintenance of motors, generators, cables, or switchgear.
Two powerful tools in one.
The Fluke 1587 and 1587 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
Like other tools that you have come to expect from Fluke, the 1587 and 1587 are rugged, reliable, and easy to use.
Whether you work on motors, generators, cables, or switch-gear, the Fluke 1587/1587 Insulation Multimeters are ideally suited to help you with your tasks.
Manufacturer Specs
| Voltage DC | |
| Maximum Voltage | 1000 V |
| Accuracy | ±(0.09%+2) |
| Maximum Resolution | 0.001V |
| Voltage AC | |
| Maximum Voltage | 1000 V |
| Accuracy | ±(2%+3) |
| Maximum Resolution | 0.1 mV |
| Current DC | |
| Maximum Amps | 400mA |
| Amps Accuracy | ±(1.0%+2) |
| Maximum Resolution | 0.01 mA |
| Current AC | |
| Maximum Amps | 400mA |
| Amps Accuracy | ±(2.0%+2) 1kHz bandwidth |
| Maximum Resolution | 0.01 mA |
| Resistance | |
| Maximum Resistance | 50 MΩ |
| Accuracy | ±(1.2%+2) |
| Maximum Resolution | 0.1Ω |
| Insulation Test | |
| Minimum Test Current @ 1kΩ/V | 1mA |
| Test Voltages | 50, 100 V |
| Maximum Resistance per Test Voltage | 100V: 100 MΩ |
| Maximum Resolution per Test Voltage | 50V: 0.01 MΩ 100V: 0.01 MΩ |
| Accuracy per Test Voltage | 50V: ±(3 % + 5) 100V: ±(3 % + 5) |
| Environmental Specifications | |
| Operating temperature | –20 °C to +55 °C |
| Storage temperature | -40°C to +60°C |
| Humidity (Without Condensation) | 0% – 95% (10 °C – 30 °C) 0% – 75% (30 °C – 40 °C) 0% – 40% (40 °C – 55 °C) |
| Operating Altitude | 2000 m |
| Safety Specifications | |
| Overvoltage category | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
| Agency Approvals | 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
| Mechanical & General Specifications | |
| Size | 203 x 100 x 50 mm (with holster) |
| Weight | 624 g |
| Warranty | 3 years |
| Battery life Alkaline | Meter use 1000 hours |
| Insulation test use | Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
| IP Rating | IP40 |
Tech Specs
Multimeters Template |
|
|---|---|
| Style | Hand-Held |
| Measures AC V | Yes |
| Measures DC V | Yes |
| Measures AC A | Yes |
| Measures DC A | Yes |
| True RMS | Yes |
| Maximum Voltage AC | 1000 V |
| Resolution AC Volts | 0.1 V (100 mV) |
| Maximum Voltage DC | 1000 V |
| Resolution DC Volts | 0.001 V (1 mV) |
| Maximum Current AC | 400 mA (0.4 A) |
| Minimum Current AC | 1 mA |
| Resolution AC Current | 0.01 mA |
| Maximum Current DC | 400 mA (0.4 A) |
| Minimum Current DC | 1 mA |
| Resolution DC Current | 0.01 mA |
| Basic Accuracy V DC | ±(0.09%+2) |
| # Digit Display | 3.75 |
| Counts | 6000 . |
| Backlight | Yes |
| Manual/Autoranging | Both |
| Decibels | No |
| Resistance | Yes |
| Frequency | Yes |
| Capacitance | Yes |
| Temperature | Yes |
| Diode Testing | Yes |
| CAT Rating | IV |
| CAT Voltage | 1,000 V, 600 V |
| Intrinsically Safe | No |
| Peak Hold | Yes |
| Overload Protector | Yes |
| Kelvin 4-Wire Measurement Capability | No |
| Wireless Display | No |
| Data Hold | Yes |
| Low-Pass Filter | Yes |
Micro / Milli / Meg Ohmmeters/Megohmmeter / Insulation Resistance Testers Template |
|
| IR Test Voltage | 100 V, 50 V |
| Maximum Insulation Resistance | 100 M Ohms (0.1 G Ohms) |
| Type | Battery |
| Minimum Insulation Resistance | 0.01 M Ohms (0.00001 G Ohms) |
| Variable Incremental Voltage | No |
| Display (Megohmmeter) | Digital |
| Continuity Test | Yes |
| Live Circuit Voltage Detection | Yes |
| Power Supply | Battery |
| Timer | No |
Test Equipment General Attributes |
|
| Unique Features | Filter for motor drive measurements (1587 only) Auto-discharge of capacitive voltage for added user protection Accepts optional Fluke TPAK™ magnetic hanging system to free your hands for other work Rugged, utility hard case allows you to bring everything you need for the job |
| Warranty | 3 YEARS |
| Safety Approval | CSA |
| IP Rating | IP40 |
| Product Weight | 1.2 LBS |
| Product Height | 1.97 IN |
| Product Length | 8.00 IN |
| Product Width | 3.94 IN |
| Shipping Weight | 4.91 LBS |
| Data Logging | No |
| Calibration Included | None |
| Battery Type | AA |
| Power Supply Voltage | Battery Powered |
| Country of Origin | United States |
| Shipping Height | 4.02 IN |
| Shipping Length | 11.57 IN |
| Shipping Width | 14.06 IN |




Valoraciones
No hay valoraciones aún.