Descripción
LogTag TRIL-8 – Multi-Use Low-Temperature Logger

- Multi-use version
- Records temperature from +40°C to as low as -80°C
- Up to 8,000 recordings – enough for the longest trip
- In-transit inspections can be recorded at the push of a button
- A real time clock provides date/ time stamps for each temperature reading
Requires LT-INT-HID or LTI-Wifi Cradle (not included) to connect to a computer to read/program the logger.
The LogTag Dry Ice “Probe-less” Temperature Logger operates, measures and stores up to 8000 temperature readings in temperature environments ranging from -80°C to +40°C (-112°F to +104°F).
Intended for use in transit monitoring of articles stored in packaging incorporating dry ice cooling agents.
Available in single-trip (SRIL-8) version.
Using the LogTag Interface and LogTag’s freely available companion software LogTag Analyzer, the LogTag Dry Ice Temperature Logger is easily configured for recording conditions including delayed start, sampling interval, number of readings and configuration of conditions to activate the ALERT indicator.
The Red Alert indicator provides an immediate indication, without access to a PC, if any readings are outside the limits specified at the time the unit was configured.
Green OK indicator provides immediate visual confirmation, without access to a PC, that the unit is operating.
Readings are downloaded using LogTag Analyzer which provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as Excel.


Manufacturer Specs
| Product Model | TRIL-8. |
| Sensor Measurement Range | -80°C to +40°C (-112°F to +104°F). |
| Operating Temperature Range | -80°C to +40°C (-112°F to +104°F). |
| Storage Temperature Range | -20°C to +40°C (-4°F to +104°F). |
| Rated Temperature Reading Accuracy | Better than ±1°C (±1.8°F) for -30°C to +20°C (-22°F to +68°F). Better than ±1.2°C (±2.1°F) for -45°C to -30°C (-49°F to -22°F) and +20°C to +40°C (+68°F to +104°F). Better than ±1.7°C (±3.1°F) for -80°C to -45°C (-112°F to -49°F). Actual performance is typically much better than the rated values. Accuracy figures can be improved by recalibration. |
| Rated Temperature Reading Resolution | Less than 0.1°C (0.2°F) for -80°C to 0°C (-112°F to +32°F). Less than 0.2°C (0.4°F) for 0°C to +20°C (+32°F to +68°F). Less than 0.5°C (0.9°F) for +20°C to +40°C (+68°F to +104°F). LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
| Sensor Reaction Time | Typically less than 5 minutes (T90) in moving air (1m/s). |
| Recording Capacity | 8031 temperature readings. 53 days @ 10min logging, 80 days @ 15min logging. |
| Sampling Interval | Configurable from 1 minute to several hours. |
| Logging Start Options | Push button start or specific date & time. |
| Recording Indication | Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator. |
| Download Time | Typically less than 5 seconds for full memory (8031 readings), depending on computer or readout device used. |
| Environmental | IP65 (roughly equivalent to NEMA 4). |
| Power Source | 3.6V low temperature chemistry Lithium (Fixed) battery. |
| Battery Life | Minimum storage life of 12 months before ‘start’. Rated for up to a total accumulative exposure of 1000hrs @ -80°C across multiple trips. |
| Real Time Clock | Built-in real time clock. Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C). |
| Size | 86mm(H) x 54.5mm(W) x 8.6mm(T). |
| Weight | 33g. |
| Case Material | Polycarbonate. |
Tech Specs
Dataloggers / Data Acquisition/Dataloggers for Environmental Variables/Temperature Dataloggers Templ |
|
|---|---|
| Max Temperature | 104 F (40 C) |
| Min Temperature | -112 F |
| Power Source | Battery |
| Battery Life | 1000 HR |
| SAMPLE RATE/Intervals | 1 minute to several hours |
| Accuracy | Better than ±1°C (±1.8°F) for -30°C to +20°C (-22°F to +68°F). Better than ±1.2°C (±2.1°F) for -45°C to -30°C (-49°F to -22°F) and +20°C to +40°C (+68°F to +104°F). Better than ±1.7°C (±3.1°F) for -80°C to -45°C (-112°F to -49°F). Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below. Accuracy figures can be improved by recalibration. |
| LCD Screen | No |
| Software Included | Yes |
Test Equipment General Attributes |
|
| Unique Features | multi-use low temperature logger |
| Warranty | 1 YEARS |
| Additional Info/Comments | 8000 readings memory capacity with up to 3 years battery life. |
| Safety Approval | CE, RoHS |
| Interfaces I/O | Other |
| Storage | Internal Memory |
| IP Rating | IP65 |
| Product Weight | 0.0728 LBS |
| Product Height | 3.38 IN |
| Product Length | 0.338 IN |
| Product Width | 2.145 IN |
| Shipping Weight | 0.0837 LBS |
| Data Logging | Yes |
| HTS/Schedule B Number | 9025.19.8085 |
| ECCN Number | EAR99 |
| Battery Type | Other |
| Power Supply Voltage | Battery Powered |
| Country of Origin | United States |




Valoraciones