Descripción
Lascar EL-GFX-D2 Dual Channel Temperature, Humidity and Dew Point Data Logger
- Dual channel Temp, RH and Dew Point data logger with external probe (supplied with x1 probe)
- -30 to +80°C (-22 to +176°F) and 0 to 100%RH measurement ranges
- Stores over 250,000 readings per channel for temperature and humidity
- Logging rates between 10 seconds and 1 hour
The data logger features a high contrast dot-matrix LCD and three buttons to navigate through an on-screen menu. This menu provides the user with access to real-time trend analysis, data summaries and the ability to start, stop and restart the data logger without the need to connect the data logger to the host-PC. Users can reset the maximum / minimum reading using the onscreen menu; this introduces an ‘event marker’ into the data which can later be viewed in the graphing software (‘Mark Events’ option) and the data file after download.
EasyLog USB Control Software
Lascar’s EasyLog USB control software is available to download from www.lascarelectronics.com/software. Easy to install and use, the control software runs under Windows™ 7/8/10 (32 & 64bit). The software is used to set-up the data logger as well as download, graph and export data to Excel. Each stored logging session is saved as a separate file.
The software allows the following parameters to be configured:
- Logger name
- Measurement parameter (°C or °F)
- Logging rate (customizable between 10 seconds and 1 hour)
- High and low temperature alarms on each channel
- Immediate, delayed, triggered and push-to-start logging
- Disable or enable LEDs and sounder with delayed activation
- Display off, on for 30 seconds after button press, or permanently on

Menu Button Functions and LCD Screen Indication

Please note that screens may vary slightly depending on model
Dimensions
- All dimensions in mm (inches)

Manufacturer Specs
| General Specifications | |
| Temperature | |
| Measurement Range | -30°C to 80°C (-22°F to 176°F) |
| Internal Resolution | 0.1°C (0.2°F) |
| Accuracy (logger error) | ± 0.3°C (0.6°F) typical |
| Relative Humidity | |
| Measurement Range | 0 to 100%RH |
| Internal Resolution | 0.1%RH |
| Accuracy (logger error) | ± 2.05%RH typical (20 to 80%RH) |
| Long Time Stability | 0.5%RH / year |
| Dew Point | |
| Accuracy (overall error) | ± 1.1°C typical (±2.0°F) |
| Logging Rate | Between 10 seconds and 1 hour |
| Battery Life* | 1 year 2 x ½ AA 3.6V |
| Dimensions of logger | 101 x 48.5 x 30.5mm (3.98 x 1.91 x 1.20”) |
| Probe Dimensions | 37 x 12 x 8mm (1.5 x 0.5 x 0.3” |
| Cable Length | 2000mm (79”) |




Valoraciones