Madgetech RFVolt2000A-160MV
- Wireless 160mVDC Voltage Data Logger with LCD
- Battery Life Indicator
- Digital Display
- Direct USB Interface
- AC Power connection via USB
Wireless Voltage Data Logger, LCD Screen
The RFVolt2000A is a wireless voltage data logger designed to connect directly to DC voltage sources. This device can also be interfaced with a wide range of voltage output sensors, including pressure sensors and CO2 sensors, as well as transmitters and other transducers. The RFVolt2000A is available in four ranges: 2.5VDC, 15VDC, 30VDC, or 160mVDC.
The RFVolt2000A-160mVDC model is a wireless, differential voltage data logger. The device is equipped with a three-position terminal block to allow for a positive, negative, and ground connection. This allows the measurement of the voltage difference between two signals tied to the same ground.
This device features an LCD screen that provides instant access to current readings, and minimum, maximum, and average statistics. Equipped with user-programmable alarms, the RFVolt2000A will alert or notify users via email or text when thresholds are breached, allowing users to take immediate action.
Manufacturer Specs
| General Specifications | |
| Memory | 32,256 Readings |
| Reading Rate | 1 reading every second up to 1 reading every 24 hours |
| Baud Rate | 250,000 |
| LED Indicators | Green, Blue & Red |
| Battery Life | 5 years typical at a 15 minute reading rate |
| Material | ABS plastic |
| Dimensions | 3.5 in x 3.17 in x 0.95 in (88.9 mm x 80.5 mm x 24.1 mm) – Data logger only |
| IP Rating | IP22 |
| Operating Environment | -20 °C to +60 °C (-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing |
| Required Interface Package | RFC1000 (wireless); USB to Mini USB Cable |
| Approvals | US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Japan (LCIE) |
| Weight | 0.2563 LBS |
| Voltage | |
| Voltage Range | 2.5 V: -3 VDC to +3 VDC 15 V: -8 VDC to +24 VDC 30 V: -8 VDC to +32 VDC 160 mV:-160 mVDC to +160 mVDC |
| Voltage Resolution | 0 to 2.5 VDC: 0.1 mVDC 0 to 15 VDC: 0.5 mVDC 0 to 30 VDC: 1.0 mVDC 0 to 160 mVDC: 5 μv |
| Voltage Calibrated Accuracy | 2.5 V: ±0.05%FSR at 25 °C (77 °F) 15 V: ±0.05%FSR at 25 °C (77 °F) 30 V: ±0.05%FSR at 25 °C (77 °F) 160 mV: ±0.01%FSR at 25 °C (77 °F) |
| Model | 2.5 V | 15 V | 30 V | 160 mV |
| Range | 0 to 2.5 VDC | 0 to 15 VDC | 0 to 30 VDC | -/+160 mVDC |
| Accuracy | ±0.05% | ±0.01% | ||
| Resolution | 0.1 mVDC | 0.5 mVDC | 0.1 mVDC | 5 μV |
Tech Specs
Dataloggers / Data Acquisition/Voltage Datalogger Template |
|
|---|---|
| Max Voltage | 160 mV (0.16 V) |
| Min Voltage | -160 mV (-0.16 V) |
| Power Source | Battery |
| Battery Life | 43800 HR |
| LCD Screen | Yes |
Test Equipment General Attributes |
|
| Safety Approval | CE |
| Product Weight | 0.2563 LBS |
| Product Height | 0.95 IN |
| Product Length | 3.5 IN |
| Product Width | 3.17 IN |
| Calibration Included | NIST Calibration |
| Battery Type | 9v |
| Power Supply Voltage | Battery Powered |




Valoraciones