Descripción

Amprobe ACD-14 PLUS
- Dual Displays – Permits simultaneous reading of Amperage & Voltage
- AC Current to 600A
- Capacitance to 3000 μF
- Temperature with Type-K Thermocouple probe
- AC and DC Voltage to 600V
- Resistance to 40MΩ
- Frequency measurement
600A Clamp-On Multimeter with Dual Display
The ACD-14 PLUS is the professionals’ choice for both HVAC and Electrical applications due to its complete set of measuring features. Its dual displays allow viewing amperage and voltage simultaneously. The ACD-14 PLUS meter offers thinner jaws over standard clamp meters.
Allowing access to tight measurement areas and still accommodating conductors up to 25 mm. Both meters also measure Capacitance and Frequency. Very versatile clamp multimeters to support all your daily measurement needs.
Other Features
- Diode test
- Hold and Maximum reading functions
- Inrush current
- Accommodates conductors up to 25 mm (1.0”) in diameter
- Auto-ranging
- Auto power off and low battery indication
- Rubber over-molded case
Manufacturer Specs
| Display | 3-3/4 digits 4000 counts, dual LCD displays |
| Update Rate | 3 per second nominal |
| Polarity | Automatic |
| Low Battery Indication | Below approx. 2.4V |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Relative Humidity | Maximum relative humidity 80% for temperatures up to 31°C (88°F) decreasing linearly to 50% relative humidity at 40°C (104°F) |
| Altitude | Indoor operation below 2000m (6,562 ft) |
| Storage Temperature | -20°C to 60°C (-4°F to 140°F), < 80% R.H. (with battery removed) |
| Temperature Coefficient | Nominal 0.15 x (specified accuracy)/°F @ 0°C – 18°C or 28°C – 40°C (32°F -64°F or 82°F – 104°F), or otherwise specified |
| Sensing | Average sensing for ACD-14 PLUS |
| Power Supply | Two 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2032). |
| Battery Life | 95 hours approx. (in DCV mode) |
| Power Consumption | 2.5 mA typical for ACD-14 PLUS |
| Low Battery Indication | Below approx. 2.4V (battery symbol appears in upper right) |
| Auto Power Off | After being idle for 30 minutes |
| APO Consumption | ACD-14 PLUS: 0.8μA typical except 25μA typical for temperature function |
| Safety | CE EN61010-1, EN61010-2-032 – Pollution Degree 2 |
| Transient Protection | 6.5kV (1.2/50μs surge) for all models |
| E.M.C. | Meets EN61326 |
| Overload Protections | ACA Clamp-on jaws: AC 600A RMS continuous “+” & “COM” terminals (all functions): 600VDC/VAC RMS |
| Dimension | L190mm X W 63mm X H 32mm (L 7.48” X W 2.48” X H 1.25”) |
| Weight | 204 g (0.450 lb approx.) |
| Jaw opening & Conductor diameter | 28 (1.1”) max |
Tech Specs
Clamp Meters/Clamp Meters Template |
|
|---|---|
| True RMS | No |
| Maximum Current AC | 600 A |
| Maximum Voltage AC | 600 V |
| Maximum Voltage DC | 600 V |
| Maximum Conductor Size | 1.1 IN |
| Resistance | Yes |
| Capacitance | Yes |
| Auto Ranging/Manual | Auto Ranging |
| In-Rush Current | Yes |
Test Equipment General Attributes |
|
| Unique Features | 5mm Thinner Jaws, Hold and Maximum Reading Functions, Microamps Measurement for Testing Flame Sensors, Rubber Over Molded Case |
| Additional Info/Comments | Line Splitter, 3000A AC Flexible Clamp-On Attachment, Temperature Adapter, Heavy Duty Test Leads with Threaded Alligator Clips |
| Product Weight | 0.45 LBS |
| Product Height | 1.25 IN |
| Product Length | 7.48 IN |
| Product Width | 2.48 IN |
| Data Logging | No |
| Battery Type | CR2032 |
| Power Supply Voltage | Battery Powered |
| Country of Origin | Taiwan |
| Shipping Height | 3.00 IN |
| Shipping Length | 10.50 IN |
| Shipping Width | 7.25 IN |
| Other Information | Display: 3-3/4 digits 4000 counts, dual LCD displays
Update Rate: 3 per second nominal Polarity: Automatic Low Battery Indication: Below approx. 2.4V Operating Temperature: 0?C to 40?C (32?F to 104?F) Relative Humidity: Maximum relative humidity 80% for temperatures up to 31?C (88?F) decreasing linearly to 50% relative humidity at 40?C (104?F) Altitude: Indoor operation below 2000m (6,562 ft) Storage Temperature: -20?C to 60?C (-4?F to 140?F), 80% R.H. (with battery removed) Temperature Coefficient: Nominal 0.15 x (specified accuracy)/?F @ 0?C – 18?C or 28?C – 40?C (32?F -64?F or 82?F – 104?F), or otherwise specified Sensing: Average sensing for ACD-14 PLUS Power Supply: Two 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2032). Battery Life: 95 hours approx. (in DCV mode) Power Consumption: 2.5 mA typical for ACD-14 PLUS Low Battery Indication: Below approx. 2.4V (battery symbol appears in upper right) Auto Power Off: After being idle for 30 minutes APO Consumption: ACD-14 PLUS: 0.8µA typical except 25µA typical for temperature function Safety: CE EN61010-1, EN61010-2-032 – Pollution Degree 2 Transient Protection: 6.5kV (1.2/50µs surge) for all models E.M.C.: Meets EN61326 Overload Protections: ACA Clamp-on jaws: AC 600A RMS continuous ?+? & ?COM? terminals (all functions): 600VDC/VAC RMS Dimension: L190mm X W 63mm X H 32mm (L 7.48? X W 2.48? X H 1.25?) Weight: 204 g (0.450 lb approx.) Jaw opening & Conductor diameter: 28 (1.1?) max |




Valoraciones
No hay valoraciones aún.