Descripción
| Fluke 59 MAX+ Infrared Thermometer
Fits your budget. Fits your job. |
Manufacturer Specs
| Model | 59 MAX | 59 MAX+ | ||
| Temperature range | -30 °C to 350 °C (-22 °F to 662 °F) | -30 °C to 500 °C (-22 °F to 932 °F) | ||
| Accuracy (Calibration geometry with ambient temperature 23 °C ±2 °C) | ≥ 0 °C: | ± 2.0 °C or ± 2.0 % of reading, whichever is greater | ≥ 0 °C: | ± 1.5 °C or ± 1.5 % of reading, whichever is greater |
| ≥ -10 °C to <0 °C: | ± 2.0 °C | ≥-10 °C to <0 °C: | ± 2.0 °C | |
| < -10 °C<0 °C: | ± 3.0 °C | < -10 °C<0 °C: | ± 3.0 °C | |
| ≥ 32 °F: | ± 4.0 °F or ± 2.0 % of reading, whichever is greater | ≥ 32 °F: | ± 3.0 °F or ± 1.5 % of reading, whichever is greater | |
| ≥ 14 °F to <32 °F | ± 4.0 °F | ≥ 14 °F to <32 °F | ± 4.0 °F | |
| ≥14 °F: | ± 6.0 °F | ≥14 °F: | ± 6.0 °F | |
| Response rime (95 %) | ≥500 ms (95 % of reading) | ≥ 500 ms (95 % of reading) | ||
| Spectral response | 8 μm to 14 μm | |||
| Emissivity | 0.10 to 1.00 | |||
| Distance to spot ratio | 8:1 (calculated at 90 % energy) |
10:1 (calculated at 90 % energy) |
||
| Display resolution | 0.1 °C (0.2 °F) | |||
| Repeatability (% of reading) | ±1.0 % of reading or ±1.0 °C (±2.0 °F), whichever is greater |
±0.8 % of reading or ±1.0 °C (±2.0 °F), whichever is greater |
||
| General specifications | |
| Power | 1 AA IEC LR06 Battery |
| Batter life | 12 hours with laser and backlight on |
| Weight | 220 g (7.76 oz) |
| Size | (156 x 80 x 50) mm (6.14 x 3.15 x 2) inches |
| Operating temperature | 0 °C to 50 °C (32 °F to 122 °F) |
| Storage temperature | -20 °C to +60 °C (-4 °F to 140 °F), (without battery) |
| Operating humidity | 10 % to 90 % RH non-condensing @ 30 °C (86 °F) |
| Operating altitude | 2000 meters above mean sea level |
| Storage altitude | 12,000 meters above mean sea level |
| Drop test | 1 m |
| Safety specifications | |
| Ingress protection rating | IP40 per IEC 60529 |
| Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |
| Compliance | EN/IEC 61010-1 |
| Laser safety | FDA and EN 60825-1 Class II |
| Electromagnetic compatibility | 61326-1 EN 61326-2 |
Tech Specs
Thermometers/IR Thermometers Template |
|
|---|---|
| IR Temperature Max | 932 F |
| IR Temperature Min | -22 F |
| Field View Ratio (Spot Ratio) | 10:1 |
| Accuracy | ≥0°C: ±2.0°C or ±2.0 % of reading, whichever is greater (≥32°F: ±4.0°F or ±2.0 % of reading, whichever is greater) ≥-10°C to <0°C: ±2.0°C (≥14°F to <32°F:±4.0°F) < -10°C: ±3.0°C (<14°F: ±6.0°F) |
| Laser Pointer | Yes |
| Backlight | Yes |
| Emissivity Adjustable | Yes |
| Alarm | Yes |
| Data Hold | Yes |
| Max./Min. | Yes |
| Memory Recall | No |
| Thermocouple Input | No |
| Food Safe | No |
Test Equipment General Attributes |
|
| Unique Features | Precise laser technology for more accurate and repeatable measurements. Large, easy-to-read backlit LCD display for easy viewing. Small and lightweight design fits easily fits into your tool box. 10:1 distance to spot ratio . IP40 rated for extra protection. Displays the minimum, maximum or average temperature, or the difference between two measurements. Hi and Lo alarms for rapid display of measurements outside the limits. Powered by one (1) AA battery. One year warranty. |
| Warranty | 1 YEARS |
| IP Rating | IP40 |
| Product Weight | 0.46 LBS |
| Product Height | 6.14 IN |
| Product Length | 3.15 IN |
| Product Width | 5 IN |
| Shipping Weight | 3.00 LBS |
| Data Logging | No |
| HTS/Schedule B Number | 9025.19.8080 |
| ECCN Number | EAR99 |
| Calibration Included | None |
| Battery Type | AA |
| Power Supply Voltage | Battery Powered |
| Country of Origin | Malaysia |
| Shipping Height | 6.14 IN |
| UPC | 095969690720 |
| Shipping Length | 3.15 IN |
| Shipping Width | 5 IN |




Valoraciones