Descripción
Comet M1200E – Multilogger Thermometer with 4 Thermocouple Inputs

- Inputs: 4 thermocouple inputs (K, J, S, B, T, and types)
- Memory: 1M values (noncyclic record), 600K values (cyclic record)
- Recording interval: 1 second to 24 hours
- Evaluate up to 16 variables
- Set alarm limits and signalization
M1200E is a battery operated datalogger that allows to monitor the actual measured values on the device display or to work with historical data in Comet Vision, where you can create table charts, PDF export, MS EXCEL. The device is designed for measuring and recording with 4 inputs for thermocouples K, J, S, B, T, N.
Included is a traceable calibration certificate in accordance with EN ISO/IEC17025.
The M1200E Multilogger can be used if the following applications:
- Healthcare and laboratories
- Food industry
- Industry and production
- Production facilities and warehouses
- Metrology
- Data centers, Server rooms
- Building management
Evaluation of up to 16 Variables
Up to 16 variables may be calculated from the four connected probes / sensors. This is the sum of the measured and calculated values. The calculated values can be a further expression of moisture – dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. It can be also the result of inter-channel conversions, for example, the difference of two connected temperature probes.
The measured values are stored in the internal non-volatile memory. Memory capacity is up to 1 million values. Logging mode can be adjusted as non-cyclic, when logging stops after filling the memory, or cyclic, when after fulfilling the memory oldest stored values are overwritten by new ones. Measured values are displayed on the screen with backlight option and the ability to change the size of display digits
Up to 4 Thermocouple Inputs
Removable inputs allow the connection thermocouple probes K, J, S, B, T, N. The direct input of bipolar voltages ranges from -60 to +140 mV. Also connect sensors with voltage output.
Alarm Limits and Indication
It is possible to set two independent alarm limits for each channel (measured or calculated value). Alarm signalization can be acoustic (built-in beeper), optical, sending an e-mail alert or an alarm output. The alarm output is for connecting an external audio or visual alarm. Users can receive alarms if the values go outside the parameters set. Alarms are indicated through an internal buzzer or 3 LEDs.
Alarm output can be used for controlling other devices when alarm is launched, such as external buzzer, telephone dialer etc.
- Type of output – open collector transistor
- Max. switching current – 100 mA
- Max. voltage on output – 24 V
- Auxiliary voltage at terminal – +5 V (only when the mains supply is present)
COMET Vision 2.0 – Analytic and Configuration Software
The recorded data can be transferred to a PC via USB cable or via GSM network for further analysis. Obtained values can be displayed in the form of a table or graph. Data and reports can be printed or exported for further processing. Comet Vision software 2.0 allows setting of device and simple data analysis. Comet database software allows collecting data from unlimited numbers of Comet devices and displaying measuring channels from unlimited number of devices on one screen. Comet cloud supports easy online access to measured data.
Manufacturer Specs
| Comet M1200E Specifications | ||||
| GENERAL TECHNICAL DATA | ||||
| Operating Temperature | -10 to +60 °C | |||
| Channels | 4x external temperature probe | |||
| Memory | 1,000,000 values (noncyclic record), 600,000 values (cyclic record) |
|||
| Recording Interval | 1 s to 24 hours | |||
| Display and Alarm Refresh | Each 10 s | |||
| Recording Mode | Noncyclic – data logging stops after filling the memory cyclic – after filling memory oldest data is overwritten by new |
|||
| Available Temperature Units | Degrees Celsius, degrees Fahrenheit | |||
| Communication Interface | USB | |||
| Power | 3x AA alkaline battery 1.5 V | |||
| Battery Life | 3 – 4 weeks | |||
| Protection Class | IP20 | |||
| Dimensions (Without Connectors) | 178 x 95 x 37mm, without attached cables | |||
| Weight (Including Batteries) | Approx. 380 g | |||
| Warranty | 3 years | |||
Tech Specs
Dataloggers / Data Acquisition/Dataloggers for Environmental Variables/Temperature Dataloggers Templ |
|
|---|---|
| Type | J, K, S, T |
| Max Temperature | 1800 C |
| Min Temperature | -200 C (-328 F) |
| Power Source | Battery |
| Battery Life | 3 WEEKS (505.38 HR) |
| Input Source | External Probe |
| # Inputs/Channels | 4 |
| SAMPLE RATE/Intervals | 1 second to 24 hours |
| Accuracy | Thermocouple K, N: ± 0.3 % from the measured value + 1.5 °C Thermocouple J: ± 0.3 % from the measured value + 1.5 °C Thermocouple S: ± 0.3 % from the measured value + 1.5 °C Thermocouple B: ± 0.3 % from the measured value + 1 °C in the range +300 to +1800 °C Thermocouple T: ± 0.3 % from the measured value + 1.5 °C |
| LCD Screen | Yes |
| Software Included | Yes |
Test Equipment General Attributes |
|
| Product Weight | 0.84 LBS |
| Shipping Weight | 0.97 LBS |




Valoraciones