Hioki LR8534 Kit – 5 Channels Wireless Strain Unit with Battery Pack

- 5 channels
- For strain measurement
- Wireless connection between LR8450-01 and measurement module, 30 m range
- Sampling rate of up to 1 ms with 5 channels
The Hioki LR8534 Kit provides 5 channels with a sampling rate of 1 ms. The wireless strain unit LR8533 can operate for about 5 hours on battery power. If the unit is charged at night, it can operate on the battery pack alone during the day.
The LR8534 cannot perform measurement by itself. Memory HiLogger LR8450-01 is required separately. By attaching the Z3230 Wireless LAN Adapter (accessory), LR8534 can be wirelessly connected to the Memory HiLogger LR8450-01.
Manufacturer Specs
| Model LR8534 Kit Specifications | |
| Connectable instrument | Memory HiLogger LR8450-01 (Wireless LAN model) |
| Control communications method | Connect wirelessly via Wireless LAN Adapter Z3230 (included) Wireless LAN (IEEE 802.11b/g/n) Communication range: 30 m (line of sight) Encryption function: WPA-PSK/WPA2-PSK, TKIP/AES Available number of channels: 1 to 11 |
| Communications buffer memory | 4 M word (volatile memory) Saves data in the event of a communications error. Data is resent when communications are restored. |
| Operating temperature and humidity | -20°C to 55°C, 80% RH (no condensation) (Charging temperature range: 5°C to 35°C) |
| Storage temperature and humidity | -20°C to 60°C, 80% RH (no condensation) |
| Vibration resistance | JIS D 1601:1995 5.3(1), Class 1A (passenger vehicle) equivalent |
| LED display | Wireless connection, measurement status, error status, AC adapter/external power, battery power, charge status |
| Automatic connection function | Available |
| Number of input channels | 5 ch (Able to set voltage or strain for each channel) |
| Input terminals | Push-button type terminal block (5 terminals per channel), outfitted with terminal block cover Set DIP switches according to measurement target. |
| Measurement target | Voltage Strain: Strain gage 1-gage method (2-wire setup), 1-gage method (3-wire setup), 2-gage method (adjacent sides), 4-gage method Strain gauge transducer |
| Input type | Balanced differential input, Simultaneous sampling of all channels (non-isolated channels) |
Tech Specs
Dataloggers / Data Acquisition/Voltage Datalogger Template |
|
|---|---|
| Power Source | AC Line, Battery |
| Battery Life | 5 HR |
| # Inputs/Channels | 5 |
| SAMPLE RATE/Intervals | 1 ms |
Test Equipment General Attributes |
|
| Warranty | 3 YEARS |
| Safety Approval | CE |
| Shipping Weight | 3 LBS |