Descripción
Hioki CM4371 True RMS 600 A AC/DC Clamp Meter for the Toughest Situations
Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. Model CM4371 is a 600A True RMS clamp meter that features stronger jaws, broader -25℃ to 65℃ operating temperature range and IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 1700 V is ideal for the clamp maintenance inspections of electrical and solar power equipment.
Damage-resistant jaws
A revised design features stronger jaws (the current sensor portion of the instrument) and a dramatic boost in the duration of the warranty from 10,000 to 30,000 open-close cycles to ensure the instrument will provide even more years of reliable use.
Clamp open/ close test

In this test, the jaws are opened and closed a specified number of times at the rate of one cycle per second. In addition, the test is continued until the jaws break to provide a better understanding of their strength. Tests like this help us improve the instrument’s durability.
-25˚C to + 65˚C
Thanks to an operating temperature range that has been expanded from the previous design (which could be used from 0°C to 40°C), the CM4371 and CM4373 can be used in freezing temperatures or on the hottest summer days.
Temperature test

In this test, we verified that the clamp meter can operate for an extended period of time while taking normal measurement in the specified temperature range.
Dustproof and waterproof performance
International Protection Code: IP54*
*Jaws (current sensor portion): IP50 Measurement functionality is maintained despite exposure to sand or dust as well as water droplets. Enhanced environmental resistance
Caution: The CM4370 Series’ waterproof enclosure is designed to enable the instrument to maintain its measurement functionality even when wet. Getting the instrument wet or measuring energized parts with wet hands increases risk of electric shock.
Dustproof and waterproof tests

In the dustproof test, the clamp meter’s enclosure is placed under reduced pressure and exposed to dust, and in the waterproof test, the instrument is sprayed with water from multiple directions in order to investigate how readily dust and water can get in.
CAT IV 600 V

The CM4371 and CM4373 can safely measure service wires with a wire-toground voltage of up to 600 V as well as wires found in distribution panels. The clamp meter series features a safe design that can withstand a transient overvoltage of 8 kV in case of a lightning strike.
DC 1700 V

The CM4371 and CM4373 can measure DC voltages of up to 1700 V, making them ideal for no-load voltage inspections of rapidly evolving solar power systems.
Giving Shape to Ease of use and Intuitive Operation

Extensive Range of Measurable Parameters

Packed with Useful Features
Testing Current has never been more Convenient


Useful Functions and Exceptional Performance


Manufacturer Specs
Hioki CM4371 True RMS 600 A AC/DC Clamp Meter Specifications
| DC Current | 20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±8 dgt. |
| AC Current | 20.00 A/600.0 A, (10 Hz to 1 kHz, True RMS) Basic accuracy: ±1.3% rdg. ±3 dgt. |
| DC Voltage | 600.0 mV to 1500 V, 5 ranges, Basic accuracy: ±0.5% rdg. ±3 dgt. |
| AC Voltage | 6.000 V to 1000 V, 4 ranges, (15 Hz to 1 kHz, True RMS) Basic accuracy: ±0.9% rdg. ±3 dgt. |
| DC+AC Current | 20.00 A/600.0 A, (10 Hz to 1 kHz, True RMS) Basic accuracy:±1.3% rdg. ±13 dgt. |
| DC+AC Voltage | 6.000 V to 1000 V, 4 ranges, Basic accuracy: ±1.0% rdg. ±7 dgt. |
| Resistance | 600.0 Ω to 600.0 kΩ, 4 ranges, Basic accuracy: ±0.7% rdg. ±5 dgt. |
| Electrostatic capacity | 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt. |
| Frequency | 9.999 Hz to 999.9 Hz, Basic accuracy: ±0.1% rdg. ±1 dgt. |
| Continuity check | Continuity threshold [ON]: 25Ω±10 Ω (Buzzor sound, red LED)Continuity threshold [OFF]: 245 Ω±10 Ω, Response time: 0.5 ms or more |
| Diode | Open terminal voltage: DC2.0 V or less, Measurement current: 200 μA, forward connection: 0.15 V to 1.8 V |
| Temperature (K) | -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C |
| Voltage detection | Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz |
| DC Power | Display range switching: 0.000 VA to 1020 kVA, Accuracy: ±2.0% rdg. ±20 dgt. |
| Crest factor | [20.00 A range] 7.5 [600.0 A range] 500.0 A or less: 3; greater than 500.0 A and less than or equal to 600.0 A: 2.5 |
| Other functions | Automatic AC/DC detection, Plus/Minus judgement function of DC A, DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds |
| Dustproof and waterproof | Grip: IP54, Jaw (the current sensor portion of the instrument)/barrier: IP50 |
| Display | Update rate: 5 times/s (excluding electrostatic capacity, frequency, and temperature) |
| Power supply | LR03 Alkaline battery ×2, Approx. 45 hours (Backlight OFF) |
| Core jaw diameter | 69 mm (2.72 in) W× 14 mm (0.55 in) D, φ33 mm (1.30 in) |
| Dimensions and mass | 65 mm (2.56 in) W × 215 mm (8.46 in) H × 35 mm (1.38 in) D mm, 340 g (12.0 oz) |
| Accessories | TEST LEAD L9207-10, CARRYING CASE C0203, LR03 Alkaline battery ×2, Instruction Manual |
Measurement specifications







Order Code
- AC/ DC Clamp Meter CM4371 (600 A AC/ DC, φ33 mm)
- AC/ DC Clamp Meter CM4373 (2000 A AC/ DC, φ55 mm)
Options
Tech Specs
Clamp Meters/Clamp Meters Template |
|
|---|---|
| True RMS | Yes |
| Maximum Current AC | 600 A |
| Maximum Current DC | 1500 A |
| Maximum Voltage AC | 1000 V |
| Maximum Voltage DC | 1500 V |
| Resistance | Yes |
| Capacitance | Yes |
| In-Rush Current | Yes |
Test Equipment General Attributes |
|
| Unique Features | 600A AC/DC |
| Warranty | 3 YEARS |
| Safety Approval | CE |
| Product Weight | 340 GRAMS (0.750 LBS) |
| Product Height | 8.46 IN |
| Product Width | 2.56 IN |
| HTS/Schedule B Number | 9030.33.3400 |
| ECCN Number | 3A992 |
| Battery Type | Other |
| Power Supply Voltage | Battery Powered |
| Country of Origin | Japan |
| Other Information | Depth:: 0.55 in. |

Damage-resistant jaws