Descripción
Fluke 62 MAX-KIT – Handheld Infrared Thermometer Kit

- Dust and water-resistant: IP54 rated for dust and water resistance
- Dual lasers: The Fluke 62+ MAX has dual rotating lasers to help you identify area to be measured The measurement area is the spot between the dots
- Hard Plastic Exterior
- Pick and Pack Foam Interior
- Detects 50-1000 Volts AC
The Fluke 64 MAX, 62 MAX+ and 62 MAX IR Thermometers have the precision you need to do your job accurately and will not break the budget. Designed and tested to survive a 3 meter drop, you can count on these lightweight, compact infrared thermometers to work when you need them to work–even in the harshest environments and when you’re not able to be there (64 MAX).

AC Voltage Sensor – 50-1000 VAC
The AC Sensor is a hand held device for determining the presence or absence of 50-1000 volts AC in insulated wires, wall receptacles, fuses, junction boxes, switches, and other voltage carrying electrical systems. The AC Sensor determines defective grounds, reverse polarity, and induced voltage.

It is not necessary to disconnect the system in question because no contact is required for operation, and current flow is not necessary to locate voltage. Simply touch the plastic tip to a connection point or move it along a wire. If AC voltage is present, the LED light in the tip will glow cherry red.

Manufacturer Specs
| Fluke 62 Max Specifications | |||||||||||||||||||||||
| Temperature Range | Fluke 62 MAX -30 °C to 500 °C (-22 °F to 932 °F) Fluke 62 MAX+ -30 °C to 650 °C (-22 °F to 1202 °F) |
||||||||||||||||||||||
| Accuracy |
|
||||||||||||||||||||||
| Response Time (95%) | Fluke 62 MAX <500 ms (95% of reading) Fluke 62 MAX+ <300 ms (95% of reading) Spectral Response 8 to 14 microns Emissivity 0.10 to 1.00 |
||||||||||||||||||||||
| Display Resolution | 0.1 °C (0.2 °F) | ||||||||||||||||||||||
| Repeatability of Readings | Fluke 62 MAX ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater Fluke 62 MAX+ ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater |
||||||||||||||||||||||
| Power | AA battery | ||||||||||||||||||||||
| Battery Life | Fluke 62 MAX 10 hours with laser and backlight on Fluke 62 MAX+ 8 hours with laser and backlight on |
||||||||||||||||||||||
| Physical Specifications |
|
||||||||||||||||||||||
| Standards and Agency Approval | Compliance EN/IEC 61010-1: 2001 Laser Safety FDA and EN 60825-1 Class II |
||||||||||||||||||||||
| AC EZ Specifications | |
| Operating Range | 50-1000 VAC |
| Operating Temperature | -20°c to +55°c |
| Weight | 39.7 grams with batteries |
| Dimensions | 5.75” in length; .75” in diameter |
| RH | |
| 95% | 0-30°c |
| 75% | 30-40°c |
| 45% | 40-55°c |
| Safety | |
| 3000m | Max. 1000 VAC, CAT III |
| Breakdown Voltage | 4000+ Volts AC |
| Outer Surface | Non-conductive body, probe and cap composed of injected molded high-impact nonflammable polycarbonate, with dielectric of 220 Volts AC potential at 60 Hertz |
| Circuit Board | Surface mounted components on FR-4 substrate |
| Light Source | One high-intensity LED for maximum illumination |
| Interior Conductor Strip | Brass strip approximately 4.75” in length |
| Operating Principle | This instrument senses an electrical field produced by AC voltage, through insulation and without touching the conductor. A constant bright red glow at the tip of the sensor will indicate the presence of voltage. |
| Printing | High adhesion pad printing for maximum resolution and definition. |
| Batteries | 2 (two) replaceable AAA Alkaline batteries included |
| All surfaces are totally non-conductive for operator safety. | |
Tech Specs
Test Equipment General Attributes |
|
|---|---|
| Product Weight | 2.6 LBS |
| Shipping Weight | 3 LBS |




Valoraciones
No hay valoraciones aún.