Descripción
Madgetech Temp1000Ex-2 – Temperature Data Logger

- Temperature Data Logger with 2 inch probe
- Compact Size
- ATEX Approved
- Available in a Variety of Probe Lengths
- 2 years Battery life
The Temp1000Ex temperature data logger carries hazardous location and intrinsically safe global certification (ATEX, IECEx, FM 3610). Includes ISO 17025 accredited calibration certificate.
Connecting and Starting the Data Logger
- Once the software is installed and running, plug the interface cable into the docking station (IFC400 or IFC406).
- Connect the USB end of the interface cable into an open USB port on the computer.
- Place the data logger into the docking station (IFC400 or IFC406).
- The data logger will automatically appear under Connected Devices within the software.
- For most applications, select Custom Start from the menu bar and choose the desired start method, reading rate and other parameters appropriate for the data logging application and click Star(Quick Start applies the most recent custom start options, Batch Start is used for managing multiple loggers at once, Real Time Start stores the dataset as it records while connected to the logger.)
- The status of the device will change to Running, Waiting to Start or Waiting to Manual Start, depending upon your start method.
- Disconnect the data logger from the interface cable and place it in the environment to measure.
Note: The device will stop recording data when the end of memory is reached or the device is stopped, unless user selectable memory wrap is enabled. At this point the device cannot be restarted until it has been re-armed by the computer
Manufacturer Specs
| Temperature Sensor | Resistance Temperature Detector (RTD) |
| Temperature Range | -40 ºC to +80 ºC (-40 °F to +176 °F) |
| Temperature Resolution | 0.01 ºC (0.018 °F) |
| Calibrated Accuracy | ±0.5 °C (0 °C to ±50 °C), ±0.9 °F (32 °F to 122 °F) |
| Memory | 32,767 Readings |
| Start Modes | Software programmable immediate or delay start, up to 2 years in advance |
| Real Time Recording | May be used with PC to monitor and record data in real time(PC interface not IS rated) |
| Reading Rate | 1 reading every 2 seconds up to 1 reading every 12 hours |
| Lethality Equations | Sterilization Units and Pasteurization Units are available within software with a click of a button |
| Calibration | Digital calibration through software |
| Calibration Date | Automatically recorded within device and displayed in software |
| Battery Type | 3.6V lithium battery included, user replaceable |
| Battery Life | 2 years typical at 15 minute reading rate |
| Data Format | Date and time stamped °C, °F, K, °R |
| Time Accuracy | 10 seconds/month (at 0 ºC to 50 ºC) |
| Required Interface Package | IFC400 or IFC406 |
| Operating System Compatibility | Windows XP SP3 or later |
| MadgeTech Software Compatibility | Standard Software version 4.2.16.0 or later Secure Software version 4.2.15.0 or later |
| Operating Environment | -40 °C to +80 °C, 0 %RH to 95 %RH (case properly sealed) |
| Dimensions | 2.65 in x .97 in dia. (67.3 mm x 24.6 mm dia.) |
| Weight | 3 oz (85 g) |
| Materials | 316 Stainless Steel/Radel |
| IP Rating | Not Rated – Caution: Do not submerge this product to retain IS rating |
| Approvals | CE ATEX Certificate #: 19ATEX0126 IECEx Certificate #: BAS 19.0109 FM3610 approval by SGS North America, Inc. |
Tech Specs
Dataloggers / Data Acquisition/Dataloggers for Environmental Variables/Temperature Dataloggers Templ |
|
|---|---|
| Type | RTD |
| Max Temperature | 80 C |
| Min Temperature | 176 F |
| Battery Life | 2 YEARS (17520 HR) |
| Accuracy | ±0.5 °C (0 °C to ±50 °C), ±0.9 °F (32 °F to 122 °F) |
Test Equipment General Attributes |
|
| Safety Approval | ATEX, CE |
| Product Weight | 0.2 LBS |
| Battery Type | Other |
| Power Supply Voltage | Battery Powered |




Valoraciones
No hay valoraciones aún.